Daily briefings
ATLAS

Research. Knowledge. Opportunity.
A clearer view of what comes next.

Medical data: tabular & CT · 7 October 2026

Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.

Daily briefing · 7 October 2026

Medical data quality is becoming part of the model, not a preprocessing footnote

Today’s evidence shows why clinical-data engineering and model evaluation cannot be separated. A large pancreatic-cancer study derives an eleven-variable risk model from routine records and validates it in a second regional health system, while a peer-reviewed imputation benchmark finds that simple interpolation can remain competitive when missingness is simulated with realistic temporal and cross-variable structure. Both results shift attention from architectural novelty to the data-generating process, timing of observations and transport beyond one cohort.

The CT studies widen that lesson. External validation supports a lung-cancer radiogenomic phenotype and automated knee-osteophyte segmentation, but other reports remain small, lesion-level or single-site. New work connects CT phenotypes with transcriptional programmes, tests quantitative coronary features across sexes, and evaluates harmonisation across more than 100,000 lung-screening scans. These are peer-reviewed technical or retrospective findings; the preprints on screening uptake, coronary urate and intracerebral-haemorrhage prognosis remain preliminary.

For researchers and builders, the practical decision is therefore not simply which model scores highest. Patient-level separation, realistic missingness, locked external evaluation, calibration and the clinical meaning of an endpoint should be designed together. The new CMS specification, admission-linked PhysioNet resource and longitudinal imaging collections can improve infrastructure, but draft schemas, credentialed access, mutable dataset cards and incomplete validation must remain visible. None of today’s findings establishes regulatory approval or proves that deployment improves patient outcomes.

Peer-reviewed research

Clinical tabular data and EHR modelling

Short-term risk prediction model for pancreatic cancer in type 2 diabetes: development and validation across two independent Chinese cohorts

Zhu and colleagues. Published 6 October 2026 in Gut; peer-reviewed original research.

Read findings, evidence and limitations

Contribution of this study: STOP-DM extends short-horizon pancreatic-cancer risk prediction beyond new-onset diabetes to people with established type 2 diabetes. A random forest uses eleven routinely available clinical predictors to estimate incident pancreatic cancer at 6, 12, 24 and 36 months.

The retrospective Tianjin Diabetes and Health Cohort supplied 330,767 people for development and internal validation; an independent Xiamen regional EHR cohort contained 105,537 people. At six months, AUROC was 0.88 in derivation, 0.89 internally and 0.86 externally. The top 5% of predicted risk captured 59.37% and 48.03% of cases in the two validation cohorts and carried 11.00-fold and 14.37-fold risk relative to the lowest-risk group.

The independent health-system result supports transport beyond one local database, but both cohorts are from China and the study is retrospective. It does not show that model-guided screening improves diagnosis, survival or harms, and prospective implementation remains necessary.

Source: https://doi.org/10.1136/gutjnl-2026-339722

Read the source · Primary source

Benchmarking imputation methods on real-world clinical time series with simulated spatio-temporal missingness

Giesa and colleagues. Published online 5 October 2026 in Nature Communications; peer-reviewed research newly indexed after the previous cutoff.

Read findings, evidence and limitations

Contribution of this study: the benchmark models both between-feature and temporal missingness with a Markov-chain generator, rather than deleting isolated values independently. It compares twenty imputation variants on MIMIC, HiRID and ICDEP and evaluates downstream in-hospital mortality or postoperative-delirium prediction.

The imputation experiments use 14,286, 11,286 and 17,811 complete-case time series; downstream cohorts contain 9,233, 8,696 and 16,020 records. Linear interpolation and last observation carried forward were robust under realistic spatio-temporal missingness, while deep spatio-temporal autoencoders mainly led after that structure was removed. Downstream differences were small and inconsistent: for example, MIMIC AUPRC was 0.274 ± 0.027 after linear interpolation versus 0.140 ± 0.027 after a bidirectional-LSTM autoencoder. Ground-truth HiRID mortality AUROC was 0.752 ± 0.069 and ICDEP delirium AUROC was 0.630 ± 0.077.

Threefold cross-validation and a common downstream classifier make methods comparable within this benchmark, but the missingness simulator is learned from each source and the construction begins from complete cases. The study does not establish prospective performance; its practical contribution is evidence that model complexity is not a substitute for realistic missingness evaluation.

Source: https://www.nature.com/articles/s41467-026-77303-8

Read the source · Primary source

CT imaging and integrated CT–clinical evidence

Radiogenomic inference of transcription factor regulatory architecture associated with a high-risk CT phenotype in Non-Small Cell Lung Cancer

Daisuke Kawahara, Misato Kishi, Yuzuha Kadooka and Yuji Murakami. First published 6 October 2026 in Medical Physics; peer-reviewed research.

Read findings, evidence and limitations

Contribution of this study: a pretreatment CT radiomics Cox model defines a high-risk NSCLC phenotype, then links that phenotype to transcriptomic pathways and inferred transcription-factor activity. The feature-selection pipeline analysed seven tumour-centred intra- and peritumoural regions; the locked eight-feature Cox model retained only features from the gross tumour volume plus a 10 mm margin.

Development and internal evaluation used 402 patients from NSCLC-Radiomics; the locked model was then applied to 110 patients from NSCLC Radiogenomics. Reported C-indices were 0.785 in training, 0.819 internally and 0.785 externally. The high-risk phenotype was associated with E2F/MYC and inflammatory programmes, and 11 of 13 transcription factors passed the false-discovery threshold.

The external cohort strengthens technical prognostic evidence, but both datasets are retrospective public collections. Gene-set, transcription-factor and LINCS compound associations are hypothesis-generating; they do not show treatment response or justify therapy selection.

Source: https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.70694

Read the source · Primary source

Sex Differences in Detection of Acute Coronary Syndrome Culprit Lesion Using Conventional and AI-Enhanced Coronary CT Angiography

Ahn and colleagues. Published 6 October 2026 as a peer-reviewed accepted manuscript in European Heart Journal – Cardiovascular Imaging.

Read findings, evidence and limitations

Contribution of this study: the EMERALD II substudy tests whether AI-derived quantitative plaque and haemodynamic features improve retrospective identification of acute-coronary-syndrome culprit lesions for women and men separately, rather than reporting only a pooled average.

The analysis includes 351 patients—90 women and 261 men—and 2,451 lesions, linking earlier coronary CT angiography to culprit and nonculprit lesions on invasive angiography. Quantitative features increased AUC from 0.78 to 0.84 in women (p=0.002) and from 0.75 to 0.82 in men (p<0.001); change in fractional flow reserve derived from CT was the strongest individual predictor.

The accessible abstract does not describe an independent external cohort or fully expose how lesion clustering within patients was handled. The result supports retrospective lesion discrimination, not a demonstrated improvement in clinical decisions or outcomes.

Source: https://academic.oup.com/ehjcimaging/advance-article-abstract/doi/10.1093/ehjci/jeag270/8866661

Read the source · Primary source

Comparison and Combination of Radiomics, Deep Learning, and Subjective Assessment for Differentiating Immature and Mature Ovarian Teratomas on Abdominal CT

Park and colleagues. Published 6 October 2026 in Journal of Computer Assisted Tomography; peer-reviewed research.

Read findings, evidence and limitations

Contribution of this study: whole-tumour, fat and calcification radiomics, a 3D ResNet18 and two radiologists’ subjective assessments are compared and combined for distinguishing immature from mature ovarian teratomas.

The matched retrospective cohort contains 31 immature and 61 mature tumours. Individual AUCs overlapped—0.817–0.820 for radiomics, 0.814 for radiologists and 0.810 for deep learning—while calibrated-probability fusion reached 0.865, an increase of 0.045 with Holm-adjusted p<0.001. In the calcified subset, fusion AUC was 0.891.

The cohort is small, and split or cross-validation details and external validation were not available in the accessible abstract. The result supports complementarity in this dataset, not deployment readiness.

Source: https://doi.org/10.1097/RCT.0000000000001927

Read the source · Primary source

Automated CT-based quantification of knee osteophytes for robotic-assisted total knee arthroplasty: a multi-cohort study

Zheng and colleagues. Published 6 October 2026 in Journal of Robotic Surgery; peer-reviewed research.

Read findings, evidence and limitations

Contribution of this study: a human-in-the-loop 3D U-Net quantifies osteophyte volume from knee CT and is tested with the model frozen in two external cohorts, followed by comparison with surgically removed osteophytes.

Development used 387 knee CT examinations; two independent external cohorts contained 100 knees each, and the prospective surgical comparison included 66 total knee arthroplasties. External median Dice scores were 0.913 and 0.909, with volume intraclass correlations of 0.977 and 0.972. Against the surgical reference, ICC was 0.876 and mean absolute error was 1.224 cm³.

This is unusually strong external technical validation for an automated CT measurement pipeline. The surgical comparator includes only accessible resected osteophytes, however, and the study does not show that using the measurements improves arthroplasty outcomes.

Source: https://doi.org/10.1007/s11701-026-04015-y

Read the source · Primary source

AutoLMISeg: A Fully Automated Pipeline for 3D Lumbar Muscle Volumetry and Densitometry on CT

Lemonnier and colleagues. Published online 5 October 2026 in Journal of Imaging Informatics in Medicine; peer-reviewed research newly indexed after the previous cutoff.

Read findings, evidence and limitations

Contribution of this study: a zero-click pipeline segments lumbar muscles from L1 to L5 and derives three-dimensional volume and density measurements without operator interaction.

In 69 retrospective CT examinations, comparison with an operator-driven reference produced Dice 0.928 ± 0.019, volume concordance correlation 0.971 and mean volume bias of +16.32 cm³, about 2%. Mean processing time was 31.2 ± 7.2 seconds versus 111.7 ± 25.9 seconds for the reference workflow.

The throughput gain is measured in a small same-site technical comparison. There is no external cohort or clinical endpoint, so the findings support workflow feasibility rather than validated sarcopenia diagnosis or outcome prediction.

Source: https://doi.org/10.1007/s10278-026-02356-6

Read the source · Primary source

An Automated Machine Learning Based Framework for Scan Level Coronary Artery Calcium Risk Stratification

Guidone and colleagues. Published online 5 October 2026 in Journal of Imaging Informatics in Medicine; peer-reviewed research newly indexed after the previous cutoff.

Read findings, evidence and limitations

Contribution of this study: scan-level coronary-calcium risk categories are predicted with pseudo-label and pixel-attenuation features, reducing dependence on dense expert annotations; radiomics and foundation-model features serve as comparators.

The in-house ECG-gated coronary CT angiography cohort contains 182 patients. Reported accuracy was 92%, 93% and 87%, with F1 of 92%, 90% and 78%, for two-, three- and five-class tasks. The approach was also applied to the public COCA chest CT collection.

The abstract does not expose the external sample size or external metrics. The endpoint is a calcium-risk category, not cardiovascular events, and the evidence does not establish clinical benefit.

Source: https://doi.org/10.1007/s10278-026-02325-z

Read the source · Primary source

Earlier this week / newly discovered peer-reviewed reading

Harmonizing the National Lung Screening Trial: Kernel resolution and field of view compensation

Krishnan and colleagues. Published 5 October 2026 in PLOS One; peer-reviewed seven-day catch-up.

Read findings, evidence and limitations

Contribution of this study: 105,191 low-dose CT scans from 23,669 National Lung Screening Trial participants had their through-plane, or z-axis, resolution resampled to 1.0 mm while native in-plane resolution was preserved. The scans were harmonised across reconstruction kernels with an anatomy-guided multipath cycleGAN and extended for inconsistent fields of view. The pipeline targets longitudinal comparability of emphysema and body-composition measurements.

The authors report reduced kernel-related variability and improved longitudinal intraclass correlations; the accessible abstract does not provide a single numerical headline suitable for comparison. Harmonisation may improve measurement consistency, but it does not establish a predictive endpoint or patient benefit.

Source: https://doi.org/10.1371/journal.pone.0352075

Read the source · Primary source

A Computed Tomography Radiomics Approach for Assessing the T Cell-Inflamed Gene Expression Profile in Hepatocellular Carcinoma and Its Association With Immunotherapy Response

Tang and colleagues. Published 4 October 2026 in Health Care Science; peer-reviewed open-access seven-day catch-up.

Read findings, evidence and limitations

Contribution of this study: CT radiomics estimates a T-cell-inflamed gene-expression profile in hepatocellular carcinoma, then tests its association with immunotherapy response and survival.

The radiogenomic cohort contains 270 patients with CT and RNA sequencing—227 for training and 43 for testing. A separate three-hospital immunotherapy cohort contains 40 patients and 209 lesions. GEP classification AUC was 0.824 in training and 0.827 in testing. For liver lesions evaluable at six months, immunotherapy-response AUC was 0.750 and response was 48.1% in predicted GEP-high lesions versus 9.3% in GEP-low lesions; across all evaluated sites, response was 30.0% versus 9.7%. Median overall survival was 17.5 versus 8.3 months.

The immunotherapy analysis is lesion-level, so multiple lesions from 40 patients may introduce within-patient clustering. Retrospective association does not establish a treatment-selection benefit.

Source: https://doi.org/10.1002/hcs2.70106

Read the source · Primary source

HepaKineticNet: Deep Learning of CT-Derived Intratumoral Heterogeneity for Overall Survival Prediction in BCLC Stage B–C Hepatocellular Carcinoma Treated with Locoregional Therapy Plus First-Line TKI and Anti–PD-1 Therapy

Li and colleagues. Published 1 October 2026 in Journal of Hepatocellular Carcinoma; peer-reviewed open-access seven-day catch-up.

Read findings, evidence and limitations

Contribution of this study: multiphase contrast-enhanced CT kinetic differences are fused with radiomics and clinical variables in a Cox model for overall-survival prediction.

Development used 359 patients—231 for training and 128 for validation—and a second-institution evaluation cohort of 95 patients. The article’s abstract and Figure 4 report an external C-index of 0.713 versus 0.651 for the clinical model (p=0.012) and one-, two- and three-year AUCs of 0.760, 0.838 and 0.909. Table 2 instead reports an integrated-model C-index of 0.722 and AUCs of 0.768, 0.825 and 0.890. Median overall survival was 9.5 months in the high-risk group and 19.0 months in the low-risk group.

This is retrospective, bi-institutional, treatment-specific prognostic evidence. Although outcome-based feature selection, normalisation, Cox fitting and thresholding excluded the second centre, the upstream segmentation and heterogeneity network was trained without outcome labels on pooled images from both centres; the authors note that this image-distribution exposure may make external performance optimistic. The three-year confidence interval is wide, the reported metric series is internally inconsistent, and the study does not demonstrate that acting on the score improves treatment or survival.

Source: https://doi.org/10.2147/JHC.S636207

Read the source · Primary source

Other new and catch-up research

Baseline prevalence of lung cancer screening and associated factors among women in breast cancer screening clinics

Odeny and colleagues. Posted 6 October 2026 as Research Square preprint v1.

Read findings, evidence and limitations

Contribution of this study: a six-year structured-EHR cohort measures low-dose CT screening uptake among women aged 50–80 with a smoking history and identifies documentation and demographic factors associated with receiving screening.

Among 9,686 women aged 50–80 with documented smoking history at two hospitals, 3,209 (33.1%) had any low-dose CT screening. Strict USPSTF eligibility could not be established because pack-years and quit dates were often missing. Documented pack-years had adjusted odds ratio 2.90, cessation medication 2.21 and current smoking 1.84. Black versus White women had adjusted odds ratio 0.87, and recorded alcohol use 0.81.

These are retrospective associations susceptible to documentation and selection effects. The endpoint is screening receipt, not cancer detection or mortality, and the manuscript has not been peer reviewed.

Source: https://doi.org/10.21203/rs.3.rs-10998785/v1

Read the source · Primary source

Coronary Urate Detected by Spectral CT Marks the Vulnerable Plaque

Fujimoto and colleagues. Posted 6 October 2026 as Research Square preprint v1.

Read findings, evidence and limitations

Contribution of this study: noncontrast dual-energy spectral CT is used to identify coronary urate and test its association with high-risk plaque, with an independent photon-counting CT cohort and micro-OCT or histopathology support.

The primary study contains 116 patients and 348 vessels; the independent cohort contains 92 patients. Urate was detected in 35.3% of patients and 17.5% of vessels. Its adjusted association with high-risk plaque was odds ratio 4.91 (95% CI 1.43–16.82), while calcium score was not associated in the reported model.

The confidence interval is wide and the design is observational. This preliminary biomarker result does not show that urate lowering prevents coronary events or that spectral CT improves outcomes.

Source: https://doi.org/10.21203/rs.3.rs-11199818/v1

Read the source · Primary source

An automated, explainable, NCCT-based clinical decision-support system for spontaneous intracerebral haemorrhage

Liu and colleagues. Posted 2 October 2026 as a medRxiv preprint; seven-day catch-up.

Read findings, evidence and limitations

Contribution of this study: automated noncontrast-CT haematoma segmentation and 1,690 radiomic features, reduced to 42, are combined with clinical variables for functional-outcome prediction.

The manuscript reports 1,876 training patients, 804 internal-validation patients and an independent external cohort of 196. The integrated model raises reported functional-outcome R² from 0.35 to 0.93 and lowers mean squared error from 387 to 61; risk AUC was 0.95 in the training cohort and 0.86 in the independent external cohort, versus 0.59 for the clinical-only comparator.

The abstract also states a total cohort of 2,680, which equals the training and internal-validation counts before adding the external 196; that arithmetic requires clarification. The very large performance gain needs independent replication, and the work is not peer reviewed.

Source: https://doi.org/10.64898/2026.09.30.26364459

Read the source · Primary source

Synthesis and practical implications

The clearest cross-study pattern is that evaluation design is itself a medical-data method. The imputation benchmark asks whether missingness resembles the real record; STOP-DM and several CT studies lock evaluation outside the development cohort; the coronary and liver studies expose whether outcomes are patient-level, lesion-level or only technical surrogates.

For clinical tables, split patients before fitting preprocessing, preserve the observation window, and report calibration and event yield alongside discrimination. For CT, keep simple baselines, test anatomy and signal preservation, and separate segmentation or image-quality scores from diagnostic and patient outcomes. When CT features are linked to molecular or treatment-response data, clustering, multiple testing and retrospective selection remain central.

The release evidence adds operational obligations: version mutable resources, retain mapping and quality-control provenance, record access conditions, and do not treat a draft specification as a live requirement. External validation can strengthen transport evidence, but it cannot substitute for prospective impact evaluation.

News from major medical data and imaging developers

CMS draft Minimum Data Set 3.0 Data Specifications v3.11.0

The U.S. Centers for Medicare & Medicaid Services posted the draft on 6 October 2026 for vendor review, targeting production on 1 October 2027. The draft adds response value 12 for GG0130 and GG0170 at discharge and OBRA or interim assessments, adds a GG0170 skip pattern and removes O0350; Section S changes are deferred to the final package.

This is a machine-readable assessment specification for nursing-home clinical-data systems, not a current reporting requirement. The public page provides a ZIP download but states no separate licence, and its timestamp lacks a timezone.

Source: https://www.cms.gov/medicare/quality/nursing-home-improvement/minimum-data-set-technical-information

PhysioNet MIMIC-CXR-Ext-MIMIC-CXR-DB v1.0

Released 1 October 2026 and newly verified in this catch-up, this relational database joins MIMIC-IV admissions with MIMIC-CXR radiographs and structured clinical content. The construction represented 227,827 imaging studies and considered 377,095 radiographs; 146,333 radiographs, or 38.8%, could be placed within an inpatient admission window. Tables cover admissions, demographics, diagnoses, laboratories, radiograph metadata, structured findings, discharge-document triples and vocabularies.

Named-entity recognition and ontology linking produce structured concepts. TypeSafe plausibility filtering retained 3,268 radiology keys (71.62%) and 12,155 discharge keys (83.69%); physicians reviewed associations rather than every extracted assertion. Admission-window matching is imperfect, and the matched subset is not the whole radiograph collection.

Access is credentialed and requires CITI training and a data-use agreement under the PhysioNet Credentialed Health Data License 1.5.0. The imaging is chest radiography, not CT; the item qualifies here because its direct contribution is a structured, admission-linked clinical database.

Source: https://physionet.org/content/mimic-cxr-ext-mimic-cxr-db/1.0/

Merlin Plus availability and version caveat

The Merlin Plus manuscript was covered in the 5 October research edition; today’s addition is the verified distribution record. The current official dataset card describes 25,494 abdominal or pelvic CT scans from 18,317 Stanford patients, paired with reports, longitudinal identifiers and dates, 44 organ or anatomy masks, and 1,193 radiologist-created tumour masks across nine organs. It reports 3,830 patients with at least two scans.

The release is untagged and mutable: the repository description still says 1,153 tumour masks, while the current card and README say 1,193. The masks and longitudinal CSV are public on Hugging Face, while the CT and report source is linked through Stanford AIMI. The repository says commercial use is not allowed and that paper content is patent-pending; Hugging Face labels the licence only as “other.” These conditions require project-specific review.

Sources: https://huggingface.co/datasets/AbdomenAtlas/MerlinPlus https://github.com/MrGiovanni/MerlinPlus

TCIA UCSD-BMETS-Longitudinal v1

The Cancer Imaging Archive dated this resource 5 October 2026 without an exact time, so its position around the previous 18:30:31 UTC cutoff is uncertain and it is treated as catch-up. The collection contains 300 adults, 1,065 longitudinal MRI time points from 2016–2023, 11,405 images and 163 GB. The data-access table separately lists 1,066 studies; its Series field is blank. It pairs serial multimodal brain MRI and tumour or resection-cavity segmentations with TSV clinical tables and data dictionaries covering demographics, diagnosis and treatment.

Segmentations were initialised with nnU-Net, manually corrected in ITK-SNAP and approved by a board-certified neuroradiologist. The dataset is single-centre, acquisition and sequence availability vary, and it provides no benchmark-performance claim. Imaging is MRI rather than CT; inclusion is based on the structured longitudinal clinical-data component. Access is under CC BY 4.0 and TCIA’s citation and usage policy.

Source: https://doi.org/10.7937/5ejb-9g94

Coverage and verification

Edition: 7 October 2026. Coverage target: 5 October 2026 18:30:31 UTC to 7 October 2026 04:00:51 UTC, plus a rolling seven-day catch-up from 30 September. Publication dates, review status and catch-up timing are stated per item.

The Research Scout’s dated run ledger records 659 metadata rows screened across PubMed and Europe PMC, with overlap between indexes, 33 primary-source records opened and four accessible full papers reviewed. Fourteen research findings were included and two retained as pending. The Release Scout’s run ledger records 24 deduplicated candidates screened, 15 official pages opened, four resources included and two retained as pending. These are workflow counts, not independent bibliographic totals.

Publisher and index coverage included Elsevier/Medical Image Analysis, Springer Nature, IEEE, RSNA, Wiley, ACM, Taylor & Francis, SAGE, Oxford and Cambridge University Presses, Science/AAAS, PNAS, PLOS, Frontiers, MDPI, the Royal Society and IOP. No additional qualifying post-cutoff item was verified from several of those publishers. PubMed and Europe PMC were searched with date filters and pagination. No new MICCAI, MIDL or MLHC proceedings item was verified.

ArXiv access was rate-limited; Web of Science and Scopus were unavailable without authorised sessions. Several publisher records exposed only abstracts. Exact release timing or immutable versions could not be verified for TCIA date-only entries, BodyMaps CancerVerse v3.5.1 or MIST v2.3.0; the latter two remain pending. No patient-level records, CT scans or DICOM files were downloaded.

Verification: two independent source checks passed; experiments were not independently reproduced.

Latest Medical data briefing