Daily briefings
ATLAS

Research. Knowledge. Opportunity.
A clearer view of what comes next.

Medical data: tabular & CT · 8 October 2026

Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.

Daily briefing · 8 October 2026

Medical data advances are increasingly about traceability, not just prediction

Today’s evidence converges on a practical requirement: a medical-data system must preserve where a value, image or model output came from. In breast-cancer trials, the MIRROR study tests AI-assisted extraction against case-report forms while retaining links to source EHR text. A nationwide claims analysis shows how laboratory-order fields reveal persistent low-value practice, while a large oncology cohort shows that reproducible associations can still have modest discrimination. Together, these studies make provenance, cohort construction and endpoint choice part of the model’s evidence.

The CT stream reaches the same conclusion. A super-resolution workflow improves skeletal models reconstructed from thick-slice clinical CT, while new research explores cone-beam CT refinement, sparse-view reconstruction and segmentation uncertainty. Yet evidence ranges from a small pediatric cohort to phantom experiments and simulated projections. CancerVerse v3.5.1 matters not because 24,422 CT scans guarantee performance, but because corrected longitudinal timing, expert-reviewed tumour masks and clinical links can support controlled evaluation.

For researchers and builders, the decision is not merely whether a headline metric rises. Preserve source references for extracted fields; split at patient level before preprocessing; record reused studies and timing offsets; test reconstruction against anatomy-sensitive endpoints; and distinguish internal validation, external transport and prospective benefit. Some findings are peer-reviewed; others are preprints or institutional releases. None establishes regulatory approval, autonomous clinical use or improved outcomes, and generative CT methods still require tests for hallucinated anatomy and domain shift.

Peer-reviewed research

Clinical tabular data and EHR modelling

Artificial intelligence for clinical data extraction from EHRs in breast cancer trials: the MIRROR study

Carlos Luis Parra-Calderón, Leonardo Mina, Manuel Ruiz-Borrego and colleagues. Published 7 October 2026 in npj Breast Cancer; peer-reviewed research. Contribution of this study: MIRROR evaluates AI-assisted extraction of structured and unstructured breast-cancer trial data against manually populated electronic case-report forms, while preserving references to the underlying source text so extracted fields can be checked.

Read findings, evidence and limitations

Contribution of this study: MIRROR evaluates AI-assisted extraction of structured and unstructured breast-cancer trial data against manually populated electronic case-report forms, while preserving references to the underlying source text so extracted fields can be checked.

The retrospective study includes 113 patients enrolled in 11 clinical trials at Virgen del Rocío University Hospital in Spain. The publisher abstract reports high accuracy, precision, recall and F1 across most domains but does not expose domain-level values in the accessible record. The endpoint is agreement with trial abstraction, not a patient outcome.

The work supports traceable assistance for trial data collection, but the cohort is small and single-site, trial documentation may be cleaner than routine records, and unstructured fields performed less consistently. It does not establish autonomous extraction or external transport without human verification.

Source: https://doi.org/10.1038/s41523-026-01060-6

Read the source · Primary source

Circulating cytokines and inflammatory indices associate with prognosis and toxicities in first line extensive stage small cell lung cancer immunochemotherapy

Ziwei Xu, Yongfeng Gao, Ling Zhou and colleagues. Published 7 October 2026 in Scientific Reports; peer-reviewed research. Contribution of this study: the authors examine whether routinely derived inflammatory indices and circulating cytokines, measured at baseline and during treatment, are associated with survival and immune-related adverse events in extensive-stage small-cell lung cancer treated with first-line chemoimmunotherapy.

Read findings, evidence and limitations

Contribution of this study: the authors examine whether routinely derived inflammatory indices and circulating cytokines, measured at baseline and during treatment, are associated with survival and immune-related adverse events in extensive-stage small-cell lung cancer treated with first-line chemoimmunotherapy.

The retrospective two-centre cohort includes 96 patients, of whom 33 developed immune-related adverse events. A nomogram had reported AUCs of 0.74 for 12-month progression-free survival and 0.89 for 24-month overall survival. High baseline IFN-γ and TNF-α were associated with shorter progression-free survival; liver metastasis, SIRI, IFN-γ and RDW were associated with shorter overall survival. The direction of the post-treatment IFN-γ association differed from baseline.

The endpoints are clinically meaningful, but the sample and toxicity-event counts are small, multiple biomarkers were examined, and no independent external validation cohort was reported. The results are exploratory associations, not evidence that the markers should direct treatment.

Source: https://doi.org/10.1038/s41598-026-73234-y

Read the source · Primary source

Association of albumin to neutrophil to lymphocyte ratio with survival cachexia and severe malnutrition in patients with cancer

Nuo Xu, Shuyao Wang, Changhong Xu and colleagues. Published 7 October 2026 in Scientific Reports; peer-reviewed research. Contribution of this study: a multicentre observational cohort evaluates the albumin-to-neutrophil-to-lymphocyte ratio as an inexpensive combined marker of nutritional and inflammatory status across cancers, using survival and malnutrition-related endpoints.

Read findings, evidence and limitations

Contribution of this study: a multicentre observational cohort evaluates the albumin-to-neutrophil-to-lymphocyte ratio as an inexpensive combined marker of nutritional and inflammatory status across cancers, using survival and malnutrition-related endpoints.

The 16,444 patients were randomly split into a discovery cohort of 11,511 and a validation cohort of 4,933 from the same multicentre resource. With a receiver-operating-characteristic-derived cutoff of 10, the reported AUC was 0.628. Higher ANLR was associated with better overall survival in discovery, HR 0.644 (95% CI 0.603–0.688), and validation, HR 0.649 (0.588–0.717). Reported odds ratios for cachexia were 0.613 and 0.646, and for severe malnutrition 0.429 and 0.463.

The large internal split supports reproducibility within the source data, but it is not independent geographic or temporal validation. Discrimination is modest, the cutoff is data-derived, and observational confounding remains; ANLR alone is not a validated clinical decision model.

Source: https://doi.org/10.1038/s41598-026-74119-w

Read the source · Primary source

Structural drivers of persistent CK-MB testing in the troponin era and a nationwide monitoring framework for cardiac biomarker stewardship

Hyejin Ryu, Se-eun Koo, Joonsang Yu, Kuenyoul Park and colleagues. Published 7 October 2026 in Scientific Reports; peer-reviewed research. Contribution of this study: a nationwide Korean claims analysis measures persistent CK-MB and myoglobin ordering despite troponin-centred guidance and proposes a monitoring framework that identifies institutional and departmental targets for laboratory stewardship.

Read findings, evidence and limitations

Contribution of this study: a nationwide Korean claims analysis measures persistent CK-MB and myoglobin ordering despite troponin-centred guidance and proposes a monitoring framework that identifies institutional and departmental targets for laboratory stewardship.

Using single-payer claims from 2010–2024 and the earliest eligible claim per patient, the study reports that troponin-only ordering remained about 3–4% through 2020 and reached 5.27% in 2024; the 15-year mean was 3.9%. Claims-defined acute myocardial infarction remained 0.4–0.8% yearly. Tertiary and general hospitals generated about 97% of claims; pooled troponin-only rates were 3.3% in cardiology, 6.9% in general internal medicine and 2.6% in emergency medicine.

The population scale is valuable for monitoring, but claims do not expose actual laboratory values or clinician rationale, the earliest-claim rule narrows repeated-use analysis, and no patient outcome was tested. The findings identify practice patterns rather than proving harm or benefit from a stewardship intervention.

Source: https://doi.org/10.1038/s41598-026-75005-1

Read the source · Primary source

CT imaging and integrated CT–clinical evidence

Adapting super-resolution reconstruction for skeletal analysis of clinical computed tomography data

An-Di Yim, Louise K. Corron and Kyra E. Stull. Released 7 October 2026 by Scientific Reports as a peer-reviewed Article in Press; final Version of Record pending. Contribution of this study: a NiftyMIC-derived super-resolution reconstruction workflow combines multiple orthogonal anisotropic clinical CT stacks to improve three-dimensional skeletal surface models when routine thick slices limit anatomical measurement.

Read findings, evidence and limitations

Contribution of this study: a NiftyMIC-derived super-resolution reconstruction workflow combines multiple orthogonal anisotropic clinical CT stacks to improve three-dimensional skeletal surface models when routine thick slices limit anatomical measurement.

The published article reports 30 people aged 0–16 from National Taiwan University Hospital. Original and super-resolved models were compared through linear measurements, surface deviation and Dice overlap. The accessible abstract reports reduced measurement error and better agreement with high-resolution PACS renderings but does not expose numerical effect sizes.

This is a small, retrospective, single-centre technical study. PACS rendering is not an independent physical ground truth, metaphyseal deviations remained, and the replication-data/preprint record describes 33 individuals while the accepted journal early-access record reports 30. The result supports research-grade skeletal modelling, not improved diagnosis or clinical outcomes.

Source: https://doi.org/10.1038/s41598-026-74030-4

Read the source · Primary source

Earlier this week / newly discovered peer-reviewed reading

How to improve electronic medical record data extraction and validation for secondary use: a proposed framework for a streamlined process

Han Chang Lim, James Grant, Anton Van Der Vegt and colleagues. Published 1 October 2026 in BMC Medical Informatics and Decision Making; peer-reviewed seven-day catch-up. Contribution of this study: a mixed-methods investigation maps governance, ownership, validation, documentation, privacy and technology challenges in secondary-use EMR extraction, then proposes staged artefacts and controls for a more reproducible workflow.

Read findings, evidence and limitations

Contribution of this study: a mixed-methods investigation maps governance, ownership, validation, documentation, privacy and technology challenges in secondary-use EMR extraction, then proposes staged artefacts and controls for a more reproducible workflow.

The 2024 study used a pilot of three participants, a questionnaire of 50 and interviews with 12 stakeholders. It identified 28 challenges and 13 enablers across people, process, information and technology; clinicians showed lower awareness and confidence, with reported differences at p<0.05. The proposed framework covers standardised extraction artefacts, ownership, catalogue and tooling practices, privacy and security.

This is a stakeholder and process study, not a patient cohort. Its samples are small and self-reported, and the framework has not been prospectively implemented or shown to improve extraction accuracy or clinical outcomes.

Source: https://doi.org/10.1186/s12911-026-03878-3

Read the source · Primary source

Deformable CT-US Registration via Anatomy-Aware Implicit Neural Representations

Agnieszka Lach, Magdalena Wysocki, Feng Li and colleagues. Submitted 6 October 2026 and accepted at the ASMUS workshop at MICCAI 2026, Springer LNCS 17276; reviewed workshop research. Contribution of this study: the method fits a per-frame SIREN deformation field for CT–ultrasound registration, using normalized-gradient-field similarity together with CT-derived stiffness, probe-contact compression, fan-geometry and Jacobian constraints to model probe-induced tissue deformation.

Read findings, evidence and limitations

Contribution of this study: the method fits a per-frame SIREN deformation field for CT–ultrasound registration, using normalized-gradient-field similarity together with CT-derived stiffness, probe-contact compression, fan-geometry and Jacobian constraints to model probe-induced tissue deformation.

Evaluation used four robotic CT–ultrasound sweeps on two abdominal phantoms and 478 manually identified landmark pairs. Target registration error was 3.97 mm, compared with 4.79 mm for rigid registration and 4.43 mm for the strongest FFD-NGF baseline; the comparison with rigid registration had p<10^-10. Folding was 0.03%. FFD-NGF achieved better PC-NCC and Dice but produced substantially more folding; in ablation, the stiffness term reduced the bone-to-soft-tissue strain ratio from 1.10 to 0.58.

This is phantom-only technical validation with no patients or clinical endpoint. Stiffness mapping is phantom-calibrated, deformation is per-frame and 2.5D, and manual landmarks can introduce observer bias.

Source: https://arxiv.org/abs/2610.08419

Read the source · Primary source

Other new and catch-up research

HyperNSDE: Personalized Neural SDEs for Joint Static–Longitudinal Clinical Data Generation

Perrine Chassat and Agathe Guilloux. Submitted 5 October 2026 on arXiv (v1, 20:54:11 UTC) and accepted at NeurIPS 2026; reviewed conference research. Contribution of this study: HyperNSDE jointly models static patient attributes, irregular longitudinal trajectories and observation timing through a HI-VAE static representation, a hypernetwork-conditioned latent neural stochastic differential equation and a latent-state intensity process. Training is non-adversarial and uses signature kernels.

Read findings, evidence and limitations

Contribution of this study: HyperNSDE jointly models static patient attributes, irregular longitudinal trajectories and observation timing through a HI-VAE static representation, a hypernetwork-conditioned latent neural stochastic differential equation and a latent-state intensity process. Training is non-adversarial and uses signature kernels.

Evaluation includes the VELOUR phase III metastatic colorectal-cancer trial with 526 patients, 23 longitudinal laboratory or vital variables, 26 static variables and a mean 21.3 visits, plus PPMI with 1,930 patients, 15 longitudinal variables, 20 static variables and a mean 11.2 visits. Against MultiNODEs, RTSGAN and DGBFGP plus HI-VAE, the authors report the best nearest-neighbour adversarial accuracy and markedly lower longitudinal maximum mean discrepancy on VELOUR, with more mixed results on PPMI. An 80/20 split was reported.

These are distributional utility and privacy evaluations, not prospective or external clinical validation. The model cannot repair cohort-selection bias or justify extrapolation to unsupported subgroups, and some advantages were dataset-dependent.

Sources: https://arxiv.org/abs/2610.07383 https://neurips.cc/virtual/2026/loc/sydney/poster/153453

Read the source · Primary source

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

Qi Lai and Yutong He. Submitted 5 October 2026 on arXiv; preprint, not peer reviewed. Contribution of this study: RefineCBCT combines pseudo-label translation, short-step diffusion and cycle consistency to refine cone-beam CT without paired planning CT, aiming to suppress artifacts while preserving anatomy for image-guided radiotherapy.

Read findings, evidence and limitations

Contribution of this study: RefineCBCT combines pseudo-label translation, short-step diffusion and cycle consistency to refine cone-beam CT without paired planning CT, aiming to suppress artifacts while preserving anatomy for image-guided radiotherapy.

The evaluation uses a public TCIA lung cohort of 20 patients and 6,721 slices and a pelvic cohort of 58 patients and 3,850 slices. Against CycleGAN, CUT, DCLGAN, SynDiff, FGDM, DiffusionMBIR, WIA-LD2ND and TLIR, the lung results were MAE 19.411, RMSE 62.758, PSNR 30.845 dB and SSIM 0.931. Pelvic results were MAE 14.905, PSNR 36.671 dB and SSIM 0.876, while SynDiff had slightly lower pelvic RMSE. In a downstream experiment, lung YOLOv8 detection improved from mAP 0.529 and IoU 0.189 on original CBCT to 0.779 and 0.735; pelvic IoU reached 0.830.

Patient-disjoint train/test details were not clear in the inspected text. The method processes independent 2D slices, lacks a quantitative volumetric-consistency measure, and has no external institutional, dose-calculation or patient-outcome validation. Detection performance is a surrogate, and unpaired generative refinement still requires explicit checks for hallucinated or removed anatomy.

Source: https://arxiv.org/abs/2610.06094

Read the source · Primary source

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

Weicheng Dai, Shantanu Ghosh and Kayhan Batmanghelich. Submitted 7 October 2026 at 00:38:54 UTC and accepted at MICCAI 2026, Springer LNCS 16888; reviewed conference research included as seven-day catch-up. Contribution of this study: PhyDiCT combines a Beer–Lambert differentiable forward model with a text-conditioned diffusion prior, Split Gibbs sampling and test-time refinement for training-free three-dimensional reconstruction from sparse X-ray projections.

Read findings, evidence and limitations

Contribution of this study: PhyDiCT combines a Beer–Lambert differentiable forward model with a text-conditioned diffusion prior, Split Gibbs sampling and test-time refinement for training-free three-dimensional reconstruction from sparse X-ray projections.

The paper evaluates 400 CT-Rate three-dimensional CT images paired with radiology reports. It synthesizes 448×448 X-rays using DiffVox and DeepDRR, with eight horizontally spaced views by default and a 1,020-mm source–detector distance. CT reports serve as proxies because no public paired CT/X-ray dataset was available. The authors report a 7.5% SSIM improvement over fully trained comparison methods; a patient-disjoint evaluation split is not reported.

A strong generative prior can create plausible but unsupported anatomy. Sparse-view simulation, lesion-level fidelity, external domain shift and diagnostic performance therefore remain unverified; this is not evidence of clinical readiness.

Source: https://arxiv.org/abs/2610.09253

Read the source · Primary source

Quantifying Volumetric Risk: Class-Aware Asymmetric Weighted Conformal Prediction for 3D Medical Image Segmentation

Shadi Alijani, Fereshteh Aghaee Meibodi and Homayoun Najjaran. Submitted 7 October 2026 at 03:51:16 UTC on arXiv; preprint, not peer reviewed and included as seven-day catch-up. Contribution of this study: the method adds latent density-ratio weighting, directional volume quantiles and class-specific false-positive/false-negative asymmetry to conformal prediction for three-dimensional segmentation under covariate shift.

Read findings, evidence and limitations

Contribution of this study: the method adds latent density-ratio weighting, directional volume quantiles and class-specific false-positive/false-negative asymmetry to conformal prediction for three-dimensional segmentation under covariate shift.

Evaluation used BraTS 2020 MRI and a synthetic multi-organ CT benchmark. At nominal 90% coverage, every class’s 95% Clopper–Pearson interval contained the target, and intervals were reported as 8–14% narrower than symmetric weighted conformal prediction.

The guarantee is marginal rather than patient-specific, depends on weighted-exchangeability and density-ratio estimation, and the CT evaluation is synthetic rather than real external clinical CT. It is useful methodological evidence, not clinical segmentation validation.

Source: https://arxiv.org/abs/2610.09392

Read the source · Primary source

Gaussian Material Fields for Volumetric Multi-Energy CT Decomposition

Jian Lin, Jiancheng Fang, Hongming Shan, Shaoyu Wang, Yang Chen and Qiegen Liu. Submitted 7 October 2026 at 05:47:00 UTC on arXiv; current-window preprint, not peer reviewed. Contribution of this study: a shared set of anisotropic three-dimensional Gaussians represents multiple materials through independent non-negative coefficients, differentiable spectral projection and material-aware adaptive density for volumetric multi-energy CT decomposition.

Read findings, evidence and limitations

Contribution of this study: a shared set of anisotropic three-dimensional Gaussians represents multiple materials through independent non-negative coefficients, differentiable spectral projection and material-aware adaptive density for volumetric multi-energy CT decomposition.

The evaluation synthesized multi-energy projections from pseudo-reference maps derived from public CT for 15 cases. Compared with the strongest reported baseline, PSNR increased by 4.03 dB, SSIM by 4.96%, and NRMSE decreased by 33.45%.

The evidence is preclinical and simulated: the sample is small, references are pseudo-ground truth, spectral physics are synthesized, and robustness to real calibration, noise and domain shift is unknown.

Source: https://arxiv.org/abs/2610.09492

Read the source · Primary source

Synthesis and practical implications

Across today’s studies, traceability appears at three levels. MIRROR retains source-text references for extracted trial fields; the EMR framework argues for documented ownership and validation; and CancerVerse corrects patient-time offsets that could otherwise contaminate longitudinal analysis. These are different interventions, but all treat provenance as a measurable property rather than administrative overhead.

For structured clinical data, patient-separated validation remains necessary but not sufficient. The cancer ANLR study reproduces associations in an internal split yet reports only modest discrimination, while the SCLC biomarker work has meaningful endpoints but too few patients and events for confident deployment. Claims-scale monitoring can find persistent practice patterns, but causal or outcome claims require designs that claims alone cannot provide.

For CT, generative reconstruction and refinement should be evaluated for anatomical faithfulness, lesion preservation and downstream validity, not only PSNR, SSIM or perceptual realism. Phantom, simulated-projection and synthetic-shift results are useful technical stages, but they must remain visibly distinct from external patient validation. Dataset versions, licensing, split provenance and study reuse should be recorded before benchmarking.

News from major medical data and imaging developers

CancerVerse v3.5.1

BodyMaps released CancerVerse v3.5.1 on 7 October 2026; it is included as a seven-day catch-up item. The update fixes inconsistent time offsets across patients in a longitudinal multimodal CT collection intended for research on multicancer screening and disease progression. The resource links CT volumes with radiology reports, pathology results, clinical variables, healthy scans and voxel-wise tumour labels.

The current card reports 24,422 CT scans, 14,599 patients, 22,344 studies, 13 annotated cancer types and 12,529 tumour annotations, with follow-up from one day to 14.4 years and as many as 26 study dates per patient. Images come from Swiss and Turkish hospitals from 2010–2025; tumour masks were drawn by 28 experts over 13 months and independently reviewed by eight board-certified radiologists with adjudication.

Access is governed by CC BY-NC-ND 4.0, with separate contact required for commercial use. The complete resource is about 3.04 TB. The hosted viewer currently fails, and the card does not expose ready-made cohort splits, site/scanner distributions, healthy-cohort counts or benchmark performance. Corrected timing improves the resource’s usability but does not itself validate a model.

Sources: https://huggingface.co/datasets/BodyMaps/CancerVerse https://huggingface.co/datasets/BodyMaps/CancerVerse/commits/main

QoL_Stress v1.0.0

PhysioNet released QoL_Stress v1.0.0 on 7 October 2026. The dataset links structured demographics, perceived-stress and state-anxiety questionnaires with ECG, electrodermal activity and heart-rate measurements collected during controlled relaxation and stress tasks.

The cohort contains 66 healthy adults, with 132 ECG records, 124 EDA records, participant and PSS-14 tables, and 132 phase-specific STAI rows. Eight expected EDA records are missing after acquisition failures. ECG was recorded after each phase rather than continuously during the tasks, and irregular EDA export timestamps should not be interpreted as one-second sampling.

The dataset is open under CC BY 4.0 and is 10.6 MB uncompressed. Its small healthy-only controlled cohort limits clinical generalisation, and the associated manuscript is still in preparation.

Source: https://physionet.org/content/qol-stress/1.0.0/

MIMIC-IV-Ext-ECG-Glucose v1.0.0

PhysioNet released MIMIC-IV-Ext-ECG-Glucose v1.0.0 on 6 October 2026; this is a seven-day catch-up item. It links each laboratory glucose value to the nearest diagnostic 12-lead ECG within plus or minus 240 minutes and adds temporal, signal-quality and insulin/dextrose annotations.

The 101-column table contains 437,671 pairs from 131,771 patients and 376,648 unique ECG studies. It includes 99,544 admissions, 30,435 ICU stays and 80,598 ICU records, with a patient-separated train/validation/test split. The authors label 22,167 pairs EXCLUDE, 295,034 CAUTION, 4,364 IDEAL and 116,106 USABLE.

Access is credentialed under the PhysioNet Credentialed Health Data License 1.5.0 and requires training and a signed data-use agreement. Important limitations include intermittent glucose measurement, limited non-ICU drug annotation, ECG reuse in 22% of pairs, heuristic unvalidated signal-quality labels, a single-centre 2008–2019 population and outcome leakage risk from target-derived columns.

Source: https://physionet.org/content/mimic-iv-ext-ecg-glucose/1.0.0/

Supportive Periodontal Therapy Clinical Examination Data v1.0.0

PhysioNet released this longitudinal structured dataset on 5 October 2026; this is a seven-day catch-up item. It provides patient baseline data, visit-level examinations, derived tables, a corrections log, a data dictionary and matching R and Python scripts for an individualized periodontal-maintenance scheduling algorithm.

The single-school retrospective cohort from Bern covers 883 patients and 11,842 visits from 1985–2011. Median follow-up was six years with nine visits per patient, and maximum follow-up was 25.7 years. The supplied code reproduces all 11,842 derived rows and 20 published stability thresholds; 63 visits required documented manual attention, including 47 from which inserted probing-depth values were removed.

The resource is open under CC BY 4.0. Interval assignment was non-random and confounded by indication and adherence; the data come from one historical Swiss care setting, and important plaque, attachment, radiographic and longitudinal smoking information is absent. The supplied model script reconstructs an earlier algorithm because the original source code is unavailable.

Source: https://physionet.org/content/supportive-periodontal-therapy/1.0.0/

Coverage and verification

Edition: 8 October 2026. Coverage target: 7 October 2026 04:00:51 UTC to 8 October 2026 03:59:42 UTC, plus a rolling seven-day catch-up from 1 October. Publication dates, review status and catch-up timing are stated per item.

ArXiv v1 timestamps were 7 October 00:38:54 UTC for PhyDiCT, 03:51:16 UTC for the conformal-segmentation paper, and 05:47:00 UTC for Gaussian Material Fields. Under the stated cutoff, the first two are catch-up items and the third is current-window. PCOS-FedSev and the XGBoost-SHAP gout classifier were not summarized because full primary-source review was not completed.

Verification: two independent source checks passed; experiments were not independently reproduced.

Latest Medical data briefing