Daily briefings
ATLAS

Research. Knowledge. Opportunity.
A clearer view of what comes next.

Medical data models are being tested where they usually fail: across sites, time and representation

Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.

Daily briefing · 12 October 2026

Today’s strongest evidence is less about a new algorithm than about what happens when medical-data systems meet a harder validation boundary. A multicentre CT-biopsy nomogram fell from an optimism-corrected AUC of 0.766 to 0.683 at the external site, while lung-nodule radiomics varied materially across seven hospitals despite an aggregate AUC near 0.92. A large colorectal-CT study and several structured-EHR models also show that impressive internal results can coexist with preprocessing, referral-spectrum or workflow dependencies.

The most useful studies make those limits measurable. A lung-cancer CT super-resolution method improved airway segmentation and some internal downstream metrics, but external prognostic gains were small or non-significant. A cross-system obstructive-sleep-apnoea model lost discrimination outside its development network, while a minute-scale paediatric EHR model and a CT foundation-model audit probe how representation choices preserve—or suppress—clinically salient signals. Peer-reviewed evidence, conference papers and preprints all contribute here, but their review status and validation strength are not interchangeable.

For builders, the practical direction is clear: lock patient-level splits before feature engineering, reserve sites or time periods until the complete pipeline is fixed, and report calibration and simple baselines alongside AUC. Data quality must be treated as part of the model: clinician entry behaviour, missingness assumptions, scanner heterogeneity and label construction can change what appears predictive. None of today’s retrospective results establishes clinical benefit or regulatory readiness; the credible next step is prospective, workflow-aware evaluation with independently governed data.

Permanent dated edition

Read the complete 12 October 2026 Medical Data briefing

Peer-reviewed research

Multicentre validation exposes transport limits in a CT-guided lung-biopsy risk model

Haiyu Liang and colleagues published “Development and validation of a nomogram for predicting chest drainage after CT-guided percutaneous lung biopsy” in Frontiers in Oncology on 12 October 2026. The retrospective study used 2,092 patients at one site for development and a frozen cohort of 400 patients at a second site for external validation. Nine pre-procedure clinical and CT-planning variables entered a ridge-logistic model, with stratified ten-fold tuning and 1,000 bootstrap repetitions for internal optimism correction.

Read findings, evidence and limitations

Haiyu Liang and colleagues published “Development and validation of a nomogram for predicting chest drainage after CT-guided percutaneous lung biopsy” in Frontiers in Oncology on 12 October 2026. The retrospective study used 2,092 patients at one site for development and a frozen cohort of 400 patients at a second site for external validation. Nine pre-procedure clinical and CT-planning variables entered a ridge-logistic model, with stratified ten-fold tuning and 1,000 bootstrap repetitions for internal optimism correction.

Apparent and optimism-corrected AUCs were 0.786 and 0.766, but external AUC fell to 0.683. External Brier score was 0.0755, calibration intercept 0.41, slope 1.13 and observed-to-expected ratio 1.44, indicating underestimation of risk. The contribution is therefore not only the nomogram: it is a transparent example of performance loss at a new site. The external cohort was underpowered and the retrospective workflow does not show that using the model improves biopsy outcomes.

Source: https://doi.org/10.3389/fonc.2026.1930072

Read the source · Primary source

Visual coronary-calcium grading on oncologic low-dose CT

Florian Enderlin and colleagues published “Accuracy of visual estimation of coronary artery calcifications on low-dose CT from oncologic FDG PET/CT” in the International Journal of Cardiovascular Imaging on 12 October 2026. Four readers graded low-dose, non-gated CT in 210 oncology patients against ECG-gated coronary-calcium CT from the same patients.

Read findings, evidence and limitations

Florian Enderlin and colleagues published “Accuracy of visual estimation of coronary artery calcifications on low-dose CT from oncologic FDG PET/CT” in the International Journal of Cardiovascular Imaging on 12 October 2026. Four readers graded low-dose, non-gated CT in 210 oncology patients against ECG-gated coronary-calcium CT from the same patients.

Interreader Krippendorff’s alpha was 0.95. Reported sensitivity and specificity were 92.2% and 95.0%, and AUCs for calcium-score cut-offs of 100, 400 and 1,000 were 0.96, 0.92 and 0.95. Negative predictive value was only 62.1%, so a negative visual grade should not be treated as a reliable rule-out. This is a reference-comparison study without a predictive train/test split; it supports opportunistic assessment research, not replacement of gated scoring or evidence of improved cardiovascular outcomes.

Source: https://doi.org/10.1007/s10554-026-03825-3

Read the source · Primary source

Phantom validation of ultrasound–cone-beam-CT fusion for spine navigation

Zerui Sun and colleagues published “Phantom-based accuracy validation of multimodal ultrasound and C-arm cone-beam CT image fusion for spine navigation” in BMC Medical Imaging on 12 October 2026. Ten independently acquired L1–L4 phantom scans were registered with a sequence of similarity alignment, iterative closest point matching and thin-plate-spline deformation; eight pedicle landmarks were held out for evaluation.

Read findings, evidence and limitations

Zerui Sun and colleagues published “Phantom-based accuracy validation of multimodal ultrasound and C-arm cone-beam CT image fusion for spine navigation” in BMC Medical Imaging on 12 October 2026. Ten independently acquired L1–L4 phantom scans were registered with a sequence of similarity alignment, iterative closest point matching and thin-plate-spline deformation; eight pedicle landmarks were held out for evaluation.

Mean target-registration error decreased from 2.98±0.23 mm to 1.26±0.08 mm, while held-out calibration error was 0.639±0.052 mm. The contribution is a controlled technical validation of a multimodal registration pipeline. It is not a patient study: instrument execution, anatomical motion and continuous real-time navigation were not tested, so the result cannot establish clinical accuracy or safety.

Source: https://doi.org/10.1186/s12880-026-02889-w

Read the source · Primary source

Heterogenous multicentre lung-CT radiomics: the LIBRA study

Hunter and colleagues published “Radiomics machine learning models for lung cancer early diagnosis in heterogenous multicentre chest CT data: LIBRA” in European Radiology Experimental on 5 October 2026. Because the publisher exposes a calendar date rather than a release time, it is included as clearly dated earlier reading rather than assigned to the rolling-window boundary. The study included 1,026 patients and 2,071 scans from seven UK hospitals with 5–30 mm indeterminate nodules. Manual segmentations produced 107 PyRadiomics features, followed by reliability filtering and 20 principal components. Mixed-effects logistic regression was compared with ComBat harmonisation and fixed-effects modelling using ten-fold cross-validation and leave-centre-out internal–external validation.

Read findings, evidence and limitations

Hunter and colleagues published “Radiomics machine learning models for lung cancer early diagnosis in heterogenous multicentre chest CT data: LIBRA” in European Radiology Experimental on 5 October 2026. Because the publisher exposes a calendar date rather than a release time, it is included as clearly dated earlier reading rather than assigned to the rolling-window boundary. The study included 1,026 patients and 2,071 scans from seven UK hospitals with 5–30 mm indeterminate nodules. Manual segmentations produced 107 PyRadiomics features, followed by reliability filtering and 20 principal components. Mixed-effects logistic regression was compared with ComBat harmonisation and fixed-effects modelling using ten-fold cross-validation and leave-centre-out internal–external validation.

Centre-specific AUCs ranged from 0.75 to 0.91. The mixed-effects radiomics model reached AUC 0.91, compared with 0.75 for ComBat and 0.88 for fixed effects; the final clinical-plus-radiomics model was about 0.92, with calibration intercept −0.036 and slope 0.89. The contribution is evidence that modelling site heterogeneity can outperform a one-size-fits-all harmonisation step. Patient scans were grouped to prevent same-patient leakage, but feature correlation filtering, standardisation and PCA are described globally rather than as training-fold-only operations, so the cross-validated AUC may be optimistic. There was no fully independent external test, and the gain over clinical and volume features, reported around AUC 0.87, was modest.

Source: https://doi.org/10.1186/s41747-026-00791-2

Read the source · Primary source

CT-to-micro-CT radiomic consistency in non-small-cell lung cancer

Brizzi and colleagues published “Bridging radiomics and histopathology: cross-modality consistency of radiomic features from CT to micro-CT in NSCLC” in European Radiology Experimental on 7 October 2026; it is included as catch-up. Sixty surgical NSCLC cases were examined with in-vivo CT, ex-vivo CT and micro-CT. Ninety-three features were compared after normalisation and volume matching using Spearman correlation, intraclass correlation and Bland–Altman analysis.

Read findings, evidence and limitations

Brizzi and colleagues published “Bridging radiomics and histopathology: cross-modality consistency of radiomic features from CT to micro-CT in NSCLC” in European Radiology Experimental on 7 October 2026; it is included as catch-up. Sixty surgical NSCLC cases were examined with in-vivo CT, ex-vivo CT and micro-CT. Ninety-three features were compared after normalisation and volume matching using Spearman correlation, intraclass correlation and Bland–Altman analysis.

Four texture features were the most reproducible and differentiated adenocarcinoma from squamous histology across modalities. The study’s contribution is an exploratory bridge from clinical imaging toward higher-resolution tissue structure, not a validated diagnostic classifier. It used one site and one operator, only partial specimens, heterogeneous acquisition and no quantitative histopathology ground truth, so the features remain candidate biomarkers.

Source: https://doi.org/10.1186/s41747-026-00780-5

Read the source · Primary source

CT foundation-model and radiomic features define colorectal-cancer subtypes

Du Cai and colleagues published “Integrated CT Foundation Model and Radiomic Features Define Clinically and Biologically Distinct Colorectal Cancer Subtypes” in Research. It was first published online on 27 August 2026 and is listed in the Research volume 9 table of contents with a 6 October 2026 date; it is included as an earlier-reading item, not as newly first published catch-up. Four non-overlapping cohorts were used: 902 cases for foundation-model fine-tuning, 3,267 for phenotype derivation, 509 for external Ningbo evaluation and 709 for neoadjuvant-response analysis. CRCFound representations and PyRadiomics features produced CT-S1 and CT-S2 phenotypes.

Read findings, evidence and limitations

Du Cai and colleagues published “Integrated CT Foundation Model and Radiomic Features Define Clinically and Biologically Distinct Colorectal Cancer Subtypes” in Research. It was first published online on 27 August 2026 and is listed in the Research volume 9 table of contents with a 6 October 2026 date; it is included as an earlier-reading item, not as newly first published catch-up. Four non-overlapping cohorts were used: 902 cases for foundation-model fine-tuning, 3,267 for phenotype derivation, 509 for external Ningbo evaluation and 709 for neoadjuvant-response analysis. CRCFound representations and PyRadiomics features produced CT-S1 and CT-S2 phenotypes.

The authors report CT-S2 associations with disease-free survival, hazard ratio 11.16, and overall survival, hazard ratio 14.29, alongside CMS4 and stromal biological programmes; external phenotype assignment reproduced separation. The scale and independent cohort are strengths, but feature-selection thresholds and preprocessing were set using the full 3,267-case derivation cohort before internal prognostic assessment, creating optimism risk. Molecular subsets were incomplete, and the retrospective associations do not show that subtype-guided treatment improves outcomes.

Source: https://doi.org/10.34133/research.1435

Read the source · Primary source

Preprints and methodological findings

OMOP-based EHR prediction for vascular outcomes

Sydney E. Browder and colleagues posted “Electronic Health Record-Based Machine Learning Models for Predicting Revascularization, Amputation, and Cardiovascular Mortality in At-Risk Patients” as a Research Square preprint on 11 October 2026. The study harmonised UNC Health data from 2014–2024 with OMOP plus a 127-variable vascular extension. It included 178,995 high-risk adults and retained 1,276 variables; eligible non-censored patients were separated at patient level into 100,000 training and 70,590 validation cases.

Read findings, evidence and limitations

Sydney E. Browder and colleagues posted “Electronic Health Record-Based Machine Learning Models for Predicting Revascularization, Amputation, and Cardiovascular Mortality in At-Risk Patients” as a Research Square preprint on 11 October 2026. The study harmonised UNC Health data from 2014–2024 with OMOP plus a 127-variable vascular extension. It included 178,995 high-risk adults and retained 1,276 variables; eligible non-censored patients were separated at patient level into 100,000 training and 70,590 validation cases.

Logistic models using inverse-probability-of-treatment weighting and MCMC-based dimensionality reduction reported AUCs of 0.984 for revascularisation, 0.926 for amputation and 0.772 for cardiovascular death. Outcome-informed feature roll-up and feature-count tuning are described before the split and are not documented as training-only, so the nominal validation AUCs may contain preprocessing optimism and are not a demonstrated clean lockbox result. The contribution is a large structured-EHR pipeline covering several vascular endpoints. It remains a single-system preprint without external validation; procedure and workflow labels may be easier to predict than biology, and the very high AUCs require independent replication.

Source: https://doi.org/10.21203/rs.3.rs-10977718/v1

Read the source · Primary source

Clinician behaviour as an upstream structured-data-quality problem

Boustani and colleagues posted “Understanding clinician engagement with electronic health records: a mixed-methods study of structured data entry using the Theory of Planned Behaviour” on medRxiv on 11 October 2026. At one London NHS Epic site, 83 doctors completed the survey, 65 supplied System Usability Scale responses, 49 completed the Theory of Planned Behaviour questionnaire and six joined interviews.

Read findings, evidence and limitations

Boustani and colleagues posted “Understanding clinician engagement with electronic health records: a mixed-methods study of structured data entry using the Theory of Planned Behaviour” on medRxiv on 11 October 2026. At one London NHS Epic site, 83 doctors completed the survey, 65 supplied System Usability Scale responses, 49 completed the Theory of Planned Behaviour questionnaire and six joined interviews.

Attitude and subjective norms, but not perceived behavioural control, were significant predictors; the theory constructs explained 56% of variance in intention. Mean usability score was 62.1. The contribution is to treat structured EHR quality as a behavioural and interface problem before modelling begins. The study is single-site, survey-based and small, with no patient endpoint; intention is not the same as complete or accurate data entry.

Source: https://www.medrxiv.org/content/10.64898/2026.10.08.26365036v1

Read the source · Primary source

Clinical and CT muscle–fat features for geriatric hip-fracture prediction

Ye and colleagues posted “Machine Learning and Logistic Regression Models Incorporating Clinical and CT-Derived Muscle-Fat Parameters for Predicting Geriatric Hip Fracture” as a Research Square preprint on 11 October 2026. The prospective single-centre cohort contained 348 adults aged at least 60 years—202 fracture cases and 146 controls. Clinical variables were combined with CT muscle and fat measurements at the femoral head, lesser trochanter and L3; patients were randomly divided 70/30 for development and validation.

Read findings, evidence and limitations

Ye and colleagues posted “Machine Learning and Logistic Regression Models Incorporating Clinical and CT-Derived Muscle-Fat Parameters for Predicting Geriatric Hip Fracture” as a Research Square preprint on 11 October 2026. The prospective single-centre cohort contained 348 adults aged at least 60 years—202 fracture cases and 146 controls. Clinical variables were combined with CT muscle and fat measurements at the femoral head, lesser trochanter and L3; patients were randomly divided 70/30 for development and validation.

After Boruta selection and comparison of eight classifiers, the logistic nomogram reported AUC 0.826 in training and 0.817 in validation. The contribution is CT–clinical integration across local and systemic body-composition measurements. There was no external site, regions of interest were manual, and activity, medication and fall-history confounding was incomplete; the case–control-like composition also limits absolute-risk interpretation.

Source: https://doi.org/10.21203/rs.3.rs-10956815/v1

Read the source · Primary source

Longitudinal EHR screening for primary aldosteronism

Lee and colleagues posted “AI-Based Screening Approach for Primary Aldosteronism Using Longitudinal EHRs” on medRxiv on 8 October 2026. Development used 22,264 patients in one Mayo system, including 1,833 primary-aldosteronism cases and 20,431 controls, followed by application to 1,279,455 adults with hypertension. An ensemble of XGBoost, random forest and Extra Trees used diagnoses, vital signs, laboratory values and medications.

Read findings, evidence and limitations

Lee and colleagues posted “AI-Based Screening Approach for Primary Aldosteronism Using Longitudinal EHRs” on medRxiv on 8 October 2026. Development used 22,264 patients in one Mayo system, including 1,833 primary-aldosteronism cases and 20,431 controls, followed by application to 1,279,455 adults with hypertension. An ensemble of XGBoost, random forest and Extra Trees used diagnoses, vital signs, laboratory values and medications.

Reported AUROC was 0.709 with expected calibration error 0.037; the first-pass screen selected 5,295 people, 0.4% of the application population. The contribution is scalable case finding from longitudinal structured data, not diagnosis. There was no external health system, and both case ascertainment and workup labels may encode referral and selection patterns.

Source: https://doi.org/10.64898/2026.10.06.26364909

Read the source · Primary source

Dynamic near-term prediction of immune-related adverse events

Gong and colleagues posted “Dynamic near-term risk prediction of clinically significant immune-related adverse events using longitudinal EHRs” on medRxiv on 8 October 2026. Development included 1,522 oncology patients and 18,744 prediction landmarks from 2015–2022; temporal evaluation used 526 patients, 6,263 landmarks and 184 positive landmarks from 2023. Every 21 days, multiscale XGBoost predicted the first structured phenotype-defined grade ≥2-compatible immune-related adverse event in the next 30 days.

Read findings, evidence and limitations

Gong and colleagues posted “Dynamic near-term risk prediction of clinically significant immune-related adverse events using longitudinal EHRs” on medRxiv on 8 October 2026. Development included 1,522 oncology patients and 18,744 prediction landmarks from 2015–2022; temporal evaluation used 526 patients, 6,263 landmarks and 184 positive landmarks from 2023. Every 21 days, multiscale XGBoost predicted the first structured phenotype-defined grade ≥2-compatible immune-related adverse event in the next 30 days.

Temporal AUROC was 0.716, AUPRC 0.067 and Brier score 0.0281; a time-aware baseline reached AUROC 0.631. The contribution is a repeated, workflow-aligned prediction horizon rather than a single baseline score. The phenotype was not independently adjudicated, precision remained low because events were rare, and there was no external site or evidence that alerts improve treatment safety.

Source: https://doi.org/10.64898/2026.10.06.26364907

Read the source · Primary source

Cross-system validation of EHR models for obstructive sleep apnoea

Hwang and colleagues posted “Machine Learning Models Using Electronic Health Record Data to Predict Obstructive Sleep Apnea” on medRxiv on 7 October 2026. Kaiser Permanente Southern California supplied development, nested cross-validation, an internal holdout of 53,048 people and temporal validation; a separate University of Kansas Medical Center cohort supplied external validation. XGBoost models used either 106 features or four minimal features.

Read findings, evidence and limitations

Hwang and colleagues posted “Machine Learning Models Using Electronic Health Record Data to Predict Obstructive Sleep Apnea” on medRxiv on 7 October 2026. Kaiser Permanente Southern California supplied development, nested cross-validation, an internal holdout of 53,048 people and temporal validation; a separate University of Kansas Medical Center cohort supplied external validation. XGBoost models used either 106 features or four minimal features.

Internal AUCs were 0.791 for any OSA and 0.768 for moderate-to-severe OSA. External AUCs fell to 0.718 and 0.690; the minimal models reached 0.725 and 0.706 and, for any OSA, exceeded STOP-BANG by 0.06–0.09 AUC. Transfer learning improved cross-system performance. The study provides an unusually clear external boundary, but sleep-study ascertainment creates referral-spectrum bias and the preprint does not establish improved diagnosis or outcomes.

Source: https://doi.org/10.64898/2026.10.05.26364806

Read the source · Primary source

Minute-scale representation learning across paediatric emergency systems

Narang and colleagues posted “Learning the electronic health record at the minute-scale” on medRxiv on 6 October 2026. MINT was trained and evaluated on 766,733 paediatric emergency-department visits spanning five health systems, ten hospitals and 16 years. The model represents event timing at minute resolution and was tested on multiple prediction tasks, including respiratory-support escalation.

Read findings, evidence and limitations

Narang and colleagues posted “Learning the electronic health record at the minute-scale” on medRxiv on 6 October 2026. MINT was trained and evaluated on 766,733 paediatric emergency-department visits spanning five health systems, ten hospitals and 16 years. The model represents event timing at minute resolution and was tested on multiple prediction tasks, including respiratory-support escalation.

The authors report superiority in 21 of 25 comparisons and improved external-system generalisation. The contribution is fine-grained temporal representation across a genuinely multi-system dataset. Exact endpoint-level margins require the paper tables, and performance may still depend on local ordering, documentation and intervention workflows; the preprint does not demonstrate prospective utility.

Source: https://doi.org/10.64898/2026.10.04.26364562

Read the source · Primary source

Hidden data challenges in clinical machine learning

Carolin Cissée and colleagues posted “Hidden Data Challenges in Clinical Machine Learning” as arXiv:2610.13350 on 9 October 2026. Using MIMIC-IV, the authors audit temporal, semantic and population alignment and show that timestamp interpretation, endpoint construction and imputation can change the signals a model uses without necessarily producing a large change in aggregate performance.

Read findings, evidence and limitations

Carolin Cissée and colleagues posted “Hidden Data Challenges in Clinical Machine Learning” as arXiv:2610.13350 on 9 October 2026. Using MIMIC-IV, the authors audit temporal, semantic and population alignment and show that timestamp interpretation, endpoint construction and imputation can change the signals a model uses without necessarily producing a large change in aggregate performance.

The contribution is an auditable framework and released code for testing whether apparently stable scores rest on unstable data definitions. The study uses one critical-care database and does not provide an external clinical outcome test; its value is methodological, warning against treating unchanged AUC as proof that preprocessing choices are harmless.

Source: https://arxiv.org/abs/2610.13350

Read the source · Primary source

Predictability bias in joint-embedding CT pretraining

Fabian Drexel and colleagues posted “The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging” as arXiv:2610.13237 on 9 October 2026. TAP-JEPA used a ViT-B/3D backbone trained on 113,611 CT volumes to study which information survives the predictive pathway.

Read findings, evidence and limitations

Fabian Drexel and colleagues posted “The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging” as arXiv:2610.13237 on 9 October 2026. TAP-JEPA used a ViT-B/3D backbone trained on 113,611 CT volumes to study which information survives the predictive pathway.

Pathology Skill fell from 0.388 to 0.271 through the pathway, versus 0.921 to 0.873 for anatomy; pathology representations moved 34.7% toward control representations. Removing final-layer pathology tokens changed scan-level margins by no more than 0.45% in four of seven probes. The contribution is a mechanistic warning: predictable anatomy can dominate sporadic pathology in self-supervised objectives. The probe results are not a clinical benchmark, and downstream harm must be established task by task.

Source: https://arxiv.org/abs/2610.13237

Read the source · Primary source

Peer-reviewed proceedings — earlier publication

Semantic-aware multimodal pretraining for medical images and tables

Yingsheng Liu and colleagues published “Unlocking the Power of Medical Tabular Data via Semantic-Aware Multimodal Pre-training” in MICCAI 2026 proceedings, whose Springer eBook was published on 24 September 2026 and softcover on 25 September. AID combines importance-aware masking with soft-label discretisation for image–tabular pretraining. SLICE-3D reserved 80,433 samples from 220 geographically isolated patients as an out-of-distribution test set. From the remaining 822-patient pool, 10,228 samples were reserved as an in-distribution test set and 310,398 entered five-fold patient-stratified cross-validation; the paper does not establish that the separate in-distribution test was patient-disjoint from all pretraining and training data. HOP added an external 284-patient cohort, and EyePACS contained 88,702 images.

Read findings, evidence and limitations

Yingsheng Liu and colleagues published “Unlocking the Power of Medical Tabular Data via Semantic-Aware Multimodal Pre-training” in MICCAI 2026 proceedings, whose Springer eBook was published on 24 September 2026 and softcover on 25 September. AID combines importance-aware masking with soft-label discretisation for image–tabular pretraining. SLICE-3D reserved 80,433 samples from 220 geographically isolated patients as an out-of-distribution test set. From the remaining 822-patient pool, 10,228 samples were reserved as an in-distribution test set and 310,398 entered five-fold patient-stratified cross-validation; the paper does not establish that the separate in-distribution test was patient-disjoint from all pretraining and training data. HOP added an external 284-patient cohort, and EyePACS contained 88,702 images.

Reported out-of-distribution AUC was 0.944 versus 0.911 for TIP, HOP AUC was 0.926, and EyePACS quadratic-weighted kappa was 0.758. The contribution is representation learning that treats tabular variables as semantic partners rather than metadata appended at the end. The evidence spans several tasks but remains retrospective and benchmark-specific.

Source: https://papers.miccai.org/miccai-2026/paper/0019_paper.pdf

Read the source · Primary source

Pulmonary-embolism risk stratification: vascular graphs add no advantage

Painchaud and colleagues published “Pulmonary Embolism Risk Stratification from CTPA and Medical Records: Vascular Graphs Are Not All You Need” in MICCAI 2026 proceedings, whose Springer eBook was published on 23 September 2026 and softcover on 24 September. The study used 353 patients with pulmonary embolism and ten-fold patient-level cross-validation with 80/10/10 train, validation and test partitions.

Read findings, evidence and limitations

Painchaud and colleagues published “Pulmonary Embolism Risk Stratification from CTPA and Medical Records: Vascular Graphs Are Not All You Need” in MICCAI 2026 proceedings, whose Springer eBook was published on 23 September 2026 and softcover on 24 September. The study used 353 patients with pulmonary embolism and ten-fold patient-level cross-validation with 80/10/10 train, validation and test partitions.

TabPFN-2 using clinical, cardiac and vascular features reached F1 86.3±6.2%, while the best graph-fusion model reached 83.8±4.9%. The contribution is a useful negative result: a more elaborate vascular-graph representation did not beat well-structured tabular and imaging-derived features. The cohort was single-centre and no comparable external dataset was available.

Source: https://papers.miccai.org/miccai-2026/paper/5113_paper.pdf

Read the source · Primary source

Temporal-calibrated dual-timepoint CT prediction of immunotherapy response in advanced NSCLC

Yao Fu and colleagues published “TCFD-Net: Temporal-Calibrated Feature Disentanglement Network for Dual-Timepoint CT-Based Immunotherapy Response Prediction in Advanced Non-small Cell Lung Cancer” in MICCAI 2026 proceedings, whose Springer eBook was published on 23 September 2026 and softcover on 24 September. The study included 1,133 patients: centre A contributed 763 patients split into 534 training, 76 validation and 153 internal test cases; centre B contributed 370 external patients. Whole-lung pre- and post-treatment CT was modelled with temporal invariant/variant disentanglement and interval gating against a RECIST response endpoint.

Read findings, evidence and limitations

Yao Fu and colleagues published “TCFD-Net: Temporal-Calibrated Feature Disentanglement Network for Dual-Timepoint CT-Based Immunotherapy Response Prediction in Advanced Non-small Cell Lung Cancer” in MICCAI 2026 proceedings, whose Springer eBook was published on 23 September 2026 and softcover on 24 September. The study included 1,133 patients: centre A contributed 763 patients split into 534 training, 76 validation and 153 internal test cases; centre B contributed 370 external patients. Whole-lung pre- and post-treatment CT was modelled with temporal invariant/variant disentanglement and interval gating against a RECIST response endpoint.

Internal and external AUCs were 0.848 and 0.828, with accuracies 0.752 and 0.754; the external M2Fusion comparator reached AUC 0.769. The external cohort and lung-oncology relevance are strengths. The result rests on one split without resampling, and comparisons were primarily imaging-based; prospective treatment-selection benefit is untested.

Source: https://papers.miccai.org/miccai-2026/paper/3685_paper.pdf

Read the source · Primary source

Through-plane CT super-resolution and downstream lung-cancer analysis

Boubnovski Martell and colleagues published “Through-Plane Attention for Anisotropic CT Super-Resolution Improves Quantitative Lung Cancer Analysis” in MICCAI 2026 proceedings, whose Springer eBook was published on 24 September 2026 and softcover on 25 September. TVSRN-V2 was trained on 250 paired volumes split 100/50/100. Downstream evaluation involved 742 NSCLC patients, including 539 from three external cohorts.

Read findings, evidence and limitations

Boubnovski Martell and colleagues published “Through-Plane Attention for Anisotropic CT Super-Resolution Improves Quantitative Lung Cancer Analysis” in MICCAI 2026 proceedings, whose Springer eBook was published on 24 September 2026 and softcover on 25 September. TVSRN-V2 was trained on 250 paired volumes split 100/50/100. Downstream evaluation involved 742 NSCLC patients, including 539 from three external cohorts.

Reported image-quality metrics were PSNR 39.16 dB and SSIM 0.946. Bronchial segmentation Dice improved by 0.16 over bicubic interpolation, histology F1 by 0.03–0.07 and internal survival C-index by 0.06. External prognostic improvements were small or non-significant. The contribution is to connect reconstruction quality to downstream tasks, while the external results show why image metrics alone cannot establish clinical value.

Source: https://papers.miccai.org/miccai-2026/paper/5469_paper.pdf

Read the source · Primary source

Multicentre benchmark for disease diagnosis from non-contrast abdominal CT

Elbakry and colleagues published “A Multi-Center Benchmark for Abdominal Disease Diagnosis and Report Generation from Non-Contrast CT” in MICCAI 2026 proceedings, whose Springer eBook was published on 24 September 2026 and softcover on 25 September. Paired non-contrast and contrast-enhanced CT/report data covered 1,254 patients, with internal splits of 760 training, 106 validation and 219 test patients plus 169 external patients. Five architectures were compared.

Read findings, evidence and limitations

Elbakry and colleagues published “A Multi-Center Benchmark for Abdominal Disease Diagnosis and Report Generation from Non-Contrast CT” in MICCAI 2026 proceedings, whose Springer eBook was published on 24 September 2026 and softcover on 25 September. Paired non-contrast and contrast-enhanced CT/report data covered 1,254 patients, with internal splits of 760 training, 106 validation and 219 test patients plus 169 external patients. Five architectures were compared.

Mean multi-organ AUC was 0.711 internally and 0.662 externally. The contribution is a shared boundary for evaluating how far models trained with richer paired supervision transport to non-contrast CT. The official project repository is public and currently provides code plus a Hugging Face dataset-download command; reproducibility still depends on successfully obtaining the advertised data and running the released dependencies.

Source: https://papers.miccai.org/miccai-2026/paper/5454_paper.pdf

Read the source · Primary source

Dual-masked autoencoding for incomplete structured EHRs

Xiao Xiang and colleagues published “Learning Representations from Incomplete EHR Data with Dual-Masked Autoencoding” in the 2026 MLHC proceedings, PMLR volume 340. AID-MAE separates intrinsic clinical missingness from deliberately augmented masks and prevents masked entries from entering the encoder, so the model learns from observed values without treating all missingness as the same signal.

Read findings, evidence and limitations

Xiao Xiang and colleagues published “Learning Representations from Incomplete EHR Data with Dual-Masked Autoencoding” in the 2026 MLHC proceedings, PMLR volume 340. AID-MAE separates intrinsic clinical missingness from deliberately augmented masks and prevents masked entries from entering the encoder, so the model learns from observed values without treating all missingness as the same signal.

Across multiple tasks on two datasets, the authors report consistent improvements over strong baselines. The contribution is a representation-learning objective tailored to real EHR missingness rather than generic tabular masking. The public abstract does not expose cohort sizes or compact task-level margins, so this edition does not quote them; the findings remain benchmark evidence rather than proof of robustness under unmeasured missing-not-at-random mechanisms.

Source: https://proceedings.mlr.press/v340/xiang26a.html

Read the source · Primary source

Synthesis and practical implications

Across CT research, transport is the recurring dividing line. The biopsy nomogram and non-contrast abdominal benchmark both weaken at an external boundary, while the super-resolution study reports small or non-significant external prognostic gains. LIBRA suggests modelling centre heterogeneity can help, but even its aggregate result lacks a fully independent test. Reconstruction and foundation-model work should therefore report whether a better representation improves segmentation, histology, prognosis or treatment-response prediction—and whether that gain survives a new site.

Structured-clinical studies show that validation design cannot compensate for uncertain provenance. Clinician entry behaviour affects what exists in the table; endpoint construction and timestamp alignment affect what counts as signal; and referral patterns affect who receives a label. Temporal and external tests are valuable, but deployment still requires prospective monitoring of calibration, workload, subgroup performance and downstream decisions.

For SYNORA and related medical-data work, the immediate standards should be patient-level partitioning before imputation or feature selection; immutable site and time holdouts; simple clinical, radiomic and image-only baselines; confidence intervals and calibration; explicit missingness assumptions; scanner/protocol provenance; and real-data evaluation even when synthetic augmentation is used. No retained study demonstrates regulatory approval or improved patient outcomes from deployment.

News from major medical data and imaging developers

NCI Imaging Data Commons skill v1.9.0 adds provenance and imaging–genomics joins

The NCI-funded Imaging Data Commons team released imaging-data-commons-skill v1.9.0 on 8 October 2026 at verified commit e686067. The MIT-licensed software update aligns with IDC data release v25 and idc-index 0.13.0, adding source-DOI provenance fields, contributor/deidentifier/DICOM-converter provenance, four DICOM index fields and missing Parquet artifacts including gdc_idc_mapping for imaging–genomics linkage and tcia_idc_subset.

The project reports tests covering provenance unnesting, null-pointer behaviour and TCGA-BRCA examples. This is provider-run software validation, not an independent data-quality or clinical benchmark. IDC collection licences remain collection-specific; the Hugging Face mirror has incomplete revision tags, DICOMweb remains on v24 and may lag, and mixed-encoding series require careful parsing.

Source: https://github.com/ImagingDataCommons/imaging-data-commons-skill/releases/tag/v1.9.0

MIMIC-IV-Ext-ECG-Glucose links structured glucose measurements with ECGs

PhysioNet published MIMIC-IV-Ext-ECG-Glucose v1.0.0 on 6 October 2026. Derived from MIMIC-IV 3.1 and MIMIC-IV-ECG 1.0, it contains 437,671 glucose–ECG pairs from 131,771 patients with 101 columns. Pairing uses a ±240-minute window, adds medication flags and a machine signal-quality index, and supplies a deterministic patient-level 80/10/10 split and SQL pipeline.

Provider descriptive checks classify 85.0% of pairs as good signal quality; median absolute timing offset is 55 minutes. The resource has no predictive benchmark. Several columns are derived from the glucose target, and patient-level summary columns use current and future records, so those fields must not be used as prediction inputs. For the 81.6% of records outside the ICU, CLEAN medication status means unannotated, not verified unexposed. It is a credentialed PhysioNet dataset under the Credentialed Health Data License and DUA 1.5.0 with required training. Other limitations include sparse laboratory sampling, reused ECGs, a heuristic rather than expert-validated signal-quality index, a single-centre 2008–2019 population and incomplete admission context.

Source: https://physionet.org/content/mimic-iv-ext-ecg-glucose/1.0.0/

Medplum v5.2.2 strengthens structured FHIR bulk export

Orangebot, Inc., doing business as Medplum, released Medplum v5.2.2 on 7 October 2026 at verified commit 04c1374 under Apache-2.0. The structured-data changes improve FHIR Bulk Data export by parsing POST bodies and repeated query values, supporting _typeFilter for system and patient exports, paginating group exports by resource type and excluding OperationDefinition resources.

The contribution is operational interoperability for exporting governed clinical tables rather than a modelling advance. Evidence is limited to the provider changelog and software tests; no benchmark of correctness across independent FHIR implementations or downstream clinical task is reported. Version 5.2.3 retained these changes and also added the CoverageEligibilityRequest.insurance.coverage SearchParameter, alongside scheduling, access-control and documentation changes.

Source: https://github.com/medplum/medplum/releases/tag/v5.2.2

Coverage and verification

Edition: 12 October 2026. Coverage was fixed at 12 October 2026, 06:05:28 UTC. The strict interval was after 11 October 2026, 06:01:55 UTC through the cutoff; rolling catch-up began 5 October 2026, 06:05:28 UTC. Preprint posting times and Crossref/DOI-deposit times were used as transparent release-time proxies when publisher pages exposed only calendar dates.

This edition retains 21 research findings and three verified releases. Web of Science and Scopus were unavailable without authorised access; broad IEEE, Elsevier and RSNA coverage was therefore limited to discoverable DOI and index metadata. TCIA’s candidate page returned HTTP 500, and no date-complete machine-readable NIH/NCI or EUCAIM feed was available. These gaps are not evidence of no other activity.

Verification: two independent source checks passed; experiments were not independently reproduced.

Latest Medical data briefing