Validation is a property of the test, not a label attached to the model
Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.
Daily briefing · 8 November 2026
The strongest theme in today’s evidence is that “validated” is not a
single state. A liver-radiomics study loses discrimination when its
compact CT model moves from a public cohort to an external hospital; a
brain-tumour CT score reports a high AUC but is developed and tested in
the same 126 patients; and a clinical-prediction-methods study finds
that algorithms with attractive discrimination can still give unstable
probabilities to individual patients. These results answer different
questions—transport, apparent classification and prediction
stability—and should not be collapsed into one claim of readiness.
The same distinction runs through the structured-data studies.
Multicentre EHRs can enlarge a cohort without validating coded
phenotypes. The ovarian study separates patients by site, but
full-cohort screening muddies the feature-selection boundary and its
small prospective cohort has short follow-up. Internal nomograms can
produce hypotheses while thresholds remain tied to local prevalence and
verification practice. Several studies expose these limits: an external
CT cohort contains few positive cases, the inflammation studies remain
observational associations, and accepted early articles still await
formatted versions.
For researchers and builders, the practical implication is to name
the evaluation target before choosing the metric. Separate patients and
sites where the intended claim requires it, nest preprocessing and
feature selection inside training, publish event counts and calibration
with AUC, and distinguish prospective data collection from prospective
clinical impact. The developer releases improve CT inference,
registration, simulation and DICOM handling, but their package tests are
engineering evidence. None establishes patient benefit, regulatory
approval or safe autonomous use.
A compact CT “virtual biopsy” approaches whole-liver radiomics internally, then drops on external validation — 7 November 2026
Angela Ammirabile, Federico Mastroleo, Renato De Martino and colleagues report “Virtual liver biopsy for detecting steatohepatitis in chemotherapy-treated patients: comparison with whole-liver radiomics and external validation,” a peer-reviewed European Radiology version of record published on 7 November.
Read findings, evidence and limitations
The study addresses chemotherapy-associated steatohepatitis in
patients with colorectal liver metastases and asks whether a manually
placed 2-mL cylinder of non-tumour liver can replace whole-liver
segmentation.
Contribution of this study: four XGBoost
configurations combine IBSI radiomics, estimated liver volume and
clinical variables. A public 105-case cohort supplied a 70/30
development/test split and five-fold cross-validation; a separate
75-patient Humanitas cohort was the external test. The histological
endpoint was chemotherapy-associated steatohepatitis. Whole-liver
radiomics reached internal AUC 0.857 (95% bootstrap CI 0.676–0.954),
while the virtual-biopsy-plus-volume model reached 0.831 (0.549–0.956;
comparison p=0.814). The compact model’s external AUC was 0.745
(0.604–0.886) with 0.680 accuracy. External testing is the main
contribution, but only 19% of the outside cohort was positive—about 14
events. The methods report that near-zero-variance and correlation
filtering were performed on training data, scaling parameters were
estimated exclusively from training data, and preprocessing was fitted
within each cross-validation fold. Manual cylinder placement,
retrospective selection and scanner/protocol differences constrain
transport. The study does not show that the model changes biopsy
decisions or outcomes. European
Radiology
A pathology-validated emergency non-contrast CT score has strong apparent performance, not independent validation — 7 November 2026
Xinli Huo, Kang Chen, Feihu Sun and colleagues report “Emergency Non-Contrast CT-Based Risk Imaging Score for Predicting the Neuropathological Grade of Brain Tumours: A Pathology-Validated Study,” a peer-reviewed final article in the Journal of Multidisciplinary Healthcare.
Read findings, evidence and limitations
It uses emergency non-contrast CT to separate WHO grade 1–2 from
grade 3–4 brain tumours before MRI or surgery.
Contribution of this study: two blinded senior
radiologists scored eight prespecified CT signs, with third-reader
adjudication, to form the 0–14 Emergency Risk Imaging Score (ERIS). All
126 single-centre patients underwent resection and pathological
confirmation. ERIS reported AUC 0.92 (95% CI 0.87–0.97); adding serum
GFAP, VEGF and S100B increased AUC to 0.94, but the DeLong comparison
was not significant (p=0.15). At ERIS 8 or above, sensitivity and
specificity were both 86%, with 88% positive and 83% negative predictive
value. Pathological confirmation and blinded image review strengthen the
endpoint. However, the score and threshold were developed and evaluated
in the same small acute-presentation cohort, with bootstrap rather than
a held-out or outside cohort. A single scanner/site and emergency
spectrum limit generalisation; the numbers are apparent performance, not
demonstrated diagnostic benefit. Journal
of Multidisciplinary Healthcare
Photon-counting CCTA links myocardial-bridge depth, pressure-gradient estimates and symptoms without proving mediation — 7 November 2026
Weihang Sun, Meiyi Song, Jiayun Li and colleagues report “Systolic pressure gradient across myocardial bridge mediates the effect of bridge depth on clinical symptoms,” a peer-reviewed European Radiology version of record.
Read findings, evidence and limitations
From 4,549 coronary CT angiograms, the authors selected 180
plaque-free patients with deep left-anterior-descending myocardial
bridges examined with photon-counting CT and machine-learning-derived CT
fractional-flow reserve; 81 were symptomatic and 99 asymptomatic.
Contribution of this study: it jointly tests
anatomical bridge depth and systolic change in CT-FFR against
angina-equivalent symptoms. Bridge depth had odds ratio 1.77 (95% CI
1.27–2.46), systolic ΔCT-FFR odds ratio 1.16 (1.05–1.27), and the
reported indirect mediation effect was 0.1881 (0.1023–0.2897). The work
connects a CT-derived structural measure with a CT-derived functional
estimate, but it is a cross-sectional, single-centre association without
a train/test split or outside cohort. Selecting plaque-free patients
with deep bridges narrows transport, symptoms are an imperfect endpoint,
and statistical mediation in this observational design does not
establish a causal mechanism or clinical benefit. European
Radiology
Prediction stability exposes uncertainty that discrimination alone can hide — accepted early article, 7 November 2026
Phichayut Phinyo, Daniel Stahl and Ewan Carr report “The influence of sample size, modelling algorithms, and hyperparameters on bootstrap-based prediction stability in clinical prediction model development: An empirical study using the HOPE dataset,” a peer-reviewed BMC Medical Research Methodology accepted early article; its final formatted version remains pending. Contribution of this study: using a 3,875-patient palliative-care dataset with 34 predictors and admission anxiety as the endpoint, the authors examine 21 combinations of seven resampled cohort sizes, LASSO, random forest and XGBoost, cross-validation, bootstrap mean absolute prediction error and instability plots.
Read findings, evidence and limitations
Larger samples reduced LASSO instability, with limited further
improvement by the full sample. Tree models sometimes produced higher
AUC but also higher individual-prediction error, fewer estimates within
a 5% error band and poorer calibration slopes; shallower or slower tree
settings improved stability with a small discrimination cost. The
contribution is methodological: model selection can change when the unit
of concern is a patient’s estimated risk rather than a rank statistic.
This is internal resampling of one dataset and endpoint, not independent
validation, and findings depend on prevalence, predictors, tuning grids
and the chosen stability definition. BMC
Medical Research Methodology
A multicentre EHR cohort estimates colorectal-cancer incidence after mucosal resection, with only 22 coded events — 7 November 2026
Mohamed H. Eldesouki, Khaled Elfert, EzzElDien A. Ibrahim and colleagues report “Incidence of Colorectal Cancer After Endoscopic Mucosal Resection: A Multicenter Electronic Health Record Cohort Study,” a peer-reviewed Journal of Gastrointestinal Cancer version of record.
Read findings, evidence and limitations
The study uses the US TriNetX Collaborative Network to follow
patients after colorectal endoscopic mucosal resection.
Contribution of this study: 3,081 patients treated
in 2016–2017 were identified, a one-year washout was applied, and 2,735
remained at risk when follow-up began. During 2018–2021, 22 ICD-10-coded
colorectal cancers occurred over 10,187.8 person-years: 2.16 per 1,000
person-years (95% CI 1.35–3.27). A sensitivity cohort aged 50–75 yielded
19 events over 8,894.8 person-years, or 2.14 per 1,000 person-years
(1.29–3.34). The multisystem EHR network broadens observation, but this
is descriptive epidemiology rather than a predictive model. Only 22
events make subgroup or annual estimates fragile, and code-based
exposure/outcome phenotypes were not independently adjudicated. The data
cannot distinguish lesion site, pathology, completeness of resection,
missed synchronous disease, recurrence, delayed surveillance or newly
arising cancer. Journal
of Gastrointestinal Cancer
A multicentre ovarian-recurrence model falls from AUC 0.94 internally to 0.76 at an independent centre — accepted early article, 7 November 2026
Yan Gao, Chenwei Yan, Wentao Li and colleagues report “Machine learning based model to predict the recurrence after fertility sparing surgery in patients with borderline ovarian tumor,” a peer-reviewed Journal of Ovarian Research accepted early article; the formatted version of record remains pending. Contribution of this study: the 589 retrospective patients were separated by site: 442 patients from three centres formed the development/internal-validation cohort, while 147 patients from a fourth centre were held out for external validation.
Read findings, evidence and limitations
An additional temporally independent prospective feasibility cohort
contained 65 patients. Ten algorithms were tuned with five-fold
cross-validation. Gradient boosting achieved internal AUC 0.94 (95% CI
0.90–0.98), sensitivity 91% and specificity 88%; external AUC 0.76
(0.70–0.82), sensitivity 75% and specificity 70%; and
prospective-feasibility AUC 0.72 (0.50–0.96). The separate-centre and
temporal cohorts test transport, but the prospective feasibility cohort
had only six recurrences and median follow-up of 15.2 months, versus a
30.6-month median recurrence time, so it is preliminary prospective data
collection rather than evidence of prospective clinical impact. The
feature-selection account is internally inconsistent: the paper says all
14 predictors were predefined and retained, yet also reports univariate
analysis across the entire 589-patient retrospective cohort and
preliminary feature-importance calculations. This muddies the clean
external-validation boundary, although no candidate variable was
ultimately excluded. The online calculator is not independent
validation. Journal
of Ovarian Research
A severe-pneumonia mortality model is conditioned on 72-hour survival and evaluated apparently — accepted early article, 7 November 2026
Fei Zhao, Fang Zheng, Lin Mei and colleagues report “Predictors of 28-day mortality and development of a clinical risk model for immunoparalyzed patients with severe pneumonia surviving the initial 72-hour stabilization: a real-world ICU retrospective observational study,” a peer-reviewed BMC Pulmonary Medicine accepted early article; final formatting remains pending. Contribution of this study: 135 ICU patients with severe pneumonia and immunoparalysis who received ceftazidime-avibactam in 2022–2025 and survived at least 72 hours were analysed with multivariable logistic regression.
Read findings, evidence and limitations
Twenty-eight-day mortality was 45.2%. Pulmonary aspergillosis had
odds ratio 16.05 and SOFA score 1.71 per unit (both p<0.001); the
combined model reported AUC 0.847 with stated good calibration. The
cohort defines a specific post-stabilisation population, not all
severe-pneumonia admissions. Survival conditioning, a small
treatment-specific regional sample and a large potentially unstable odds
ratio limit interpretation. The accessible record exposes neither a
held-out/outside cohort nor an AUC confidence interval; this is apparent
retrospective performance, not evidence of earlier warning or improved
care. BMC
Pulmonary Medicine
A NASH fibrosis nomogram beats common scores internally but has no held-out cohort — accepted early article, 7 November 2026
Wen-Jing Luo, Xian-Wen Dong, Qiao-Su Zhao and colleagues report “Nomogram Model for Screening Significant Liver Fibrosis (F2–F3) in NASH Using Lipoprotein(a) Combined with Lipid Metabolism, Oxidative Stress, and Coagulation-Fibrinolysis Parameters,” a peer-reviewed Frontiers in Pharmacology accepted early article.
Read findings, evidence and limitations
It was accepted on 7 November and awaits the final formatted
version.
Contribution of this study: 303 biopsy-confirmed
NASH cases—147 with F2–F3 and 156 with F0–1—underwent univariate
screening, ten-fold-cross-validated LASSO, multivariable logistic
regression and backward AIC selection. The BMI, triglyceride,
lipoprotein(a), GGT and D-dimer nomogram reported AUC 0.838 (95% CI
0.791–0.877), sensitivity 78.91% and specificity 75.64%. AUCs were 0.659
for FIB-4, 0.692 for NFS and 0.557 for APRI; subgroup AUCs ranged from
0.770 to 0.871. All selection and evaluation used the same retrospective
cohort. Cross-validation during LASSO does not turn the final reported
performance or subgroups into external validation. Recruitment spectrum,
biopsy sampling and the operating threshold need independent testing
before local screening use. Frontiers
in Pharmacology
Routine biochemistry and ultrasound stratify suspected bile-duct stones only within the studied pathway — accepted early article, 7 November 2026
MaoPing Zhou, CaiYun Jiang, HanXiao Zhou and colleagues report “A Prediction Model Based on Ultrasonographic Common Bile Duct Diameter and Routine Cholestatic Biochemistry for Common Bile Duct Stones in Acute Cholecystitis With Suspected Choledocholithiasis,” a peer-reviewed Frontiers in Surgery accepted early article; the final formatted version is pending. Contribution of this study: age, ultrasound common-bile-duct diameter, bilirubin, alkaline phosphatase and GGT were combined in 401 selected patients, 162 of whom had stones confirmed through a composite of ERCP, intraoperative cholangiography, MRCP, EUS or surgical findings during the index admission.
Read findings, evidence and limitations
The model reported AUC 0.828, Brier score 0.166 and, at a 0.37
cutoff, 78.4% sensitivity and 72.8% specificity. Observed stone rates
across predicted-risk tertiles were 10.4%, 38.1% and 72.9%. The model
uses routinely available data, but the accessible abstract does not
expose an independent holdout or external site. Differential
verification across several reference tests and selection of
already-suspected patients constrain calibration and transport. The
cutoff and tertiles remain internal estimates, not universal triage
thresholds. Frontiers
in Surgery
Week-six inflammation change is associated with pathological response, not validated as a pretreatment predictor — accepted early article, 7 November 2026
Lili Chai and Lin Chen report “Early changes in the systemic inflammation response index and pathological response during neoadjuvant pembrolizumab plus chemotherapy in triple-negative breast cancer,” a peer-reviewed Frontiers in Immunology accepted early article; final formatting remains pending. Contribution of this study: in 204 consecutive stage II–III patients at one centre, 184 had paired baseline and week-six blood counts.
Read findings, evidence and limitations
Pathological complete response occurred in 131 of 204 overall and 121
of 184 paired cases. Each halving of the week-six-to-baseline systemic
inflammation response index was associated with pCR at adjusted odds
ratio 1.93 (95% CI 1.20–3.11; p=0.006). Treatment interruption was not
significantly associated with pCR (aOR 0.77, 0.49–1.20), and a day-42
landmark event-free-survival analysis was also nonsignificant (aHR 0.72,
0.41–1.28). The time-varying marker is observational and measured after
treatment begins. Missing paired laboratories, G-CSF, infection,
steroids and delivered therapy can influence both the biomarker and
outcome; event-free survival is immature. There is no split or external
cohort, and the finding is not pretreatment prediction or
treatment-effect evidence. Frontiers
in Immunology
EMBARC-BRIDGE links systemic inflammation to bronchiectasis severity without an independent prediction test — accepted manuscript, 7 November 2026
Chloe Hughes and EMBARC-BRIDGE collaborators report “Systemic Inflammation in Bronchiectasis: Data from the EMBARC-BRIDGE Study,” a peer-reviewed American Journal of Respiratory and Critical Care Medicine accepted manuscript published online on 7 November; copyediting and typesetting remain pending. Contribution of this study: the international multicentre observational cohort used Olink serum profiling in 487 participants and a peripheral-neutrophil functional substudy.
Read findings, evidence and limitations
PR3, AZU1, MPO, ST2 and GDF-15 were associated with worse disease
severity, lung function, symptoms and severe exacerbations. Neutrophils
showed lower CD11b, higher CXCR2 and reduced basal degranulation while
preserving response to lipopolysaccharide. The journal article matures
earlier conference reporting, but these are correlated observational
associations, not a validated prognostic model or treatment target. The
accessible abstract does not expose the functional-substudy count, full
multiplicity handling or outside replication. Causal interpretation and
clinical use require independent confirmation. AJRCCM
PSM-Qual measures assessor agreement, not whether a propensity-score study is unbiased — 7 November 2026
Sangeeth Das, Sabrina Casucci, Forough Mahpouya and Alexander Nikolaev report “Treatment effect estimation from observational data in healthcare: study designs, inherent biases, and a propensity score-focused quality assessment scale,” a peer-reviewed Health Services and Outcomes Research Methodology version of record. Contribution of this study: PSM-Qual explicitly evaluates comparator definition, data quality, de-confounding and inference validity, and interpretability.
Read findings, evidence and limitations
Two independent assessors applied it to 127 published
propensity-score studies. Item agreement ranged from 82.0% to 99.2%;
Cohen’s kappa ranged from 0.377 to 0.922 and weighted kappa from 0.382
to 0.958. The scale makes recurrent structured-data design failures
easier to audit, but inter-rater reliability is not construct validity.
The study does not show that PSM-Qual predicts true bias better than
ROBINS-I, the Newcastle–Ottawa Scale or target-trial assessment, and the
same assessor pair created and tested the instrument. Its contribution
is a candidate review framework, not a guarantee that a high-scoring
estimate is causal. Health
Services and Outcomes Research Methodology
No novel medical-data preprint or reviewed-proceedings record was
verified in the strict interval. Several delayed-index CT and
CT–clinical papers surfaced during the rolling seven-day search, but
they had already appeared in the Medical Data editions of 5 or 6
November and were not repeated. A prospective PET/CT oncology study was
also excluded because its quantitative predictors were PET-derived
rather than a substantive CT-data contribution.
Synthesis and practical implications
Today’s studies illustrate at least four different meanings of
validation. The liver-radiomics work tests transport to another
hospital; the brain and fibrosis scores report apparent performance in
their development cohorts; the ovarian study uses internal five-fold
cross-validation, a separate-centre external cohort and a small
temporally prospective feasibility cohort, although full-cohort
exploratory screening muddies the feature-selection boundary; and the
prediction-stability paper asks whether an individual’s probability
changes when the development sample changes. These are not
interchangeable. A report should state the patient, site and time
separation; event count; preprocessing boundary; endpoint; calibration;
and intended decision.
High AUCs also need denominators and comparators. External
liver-model performance rests on roughly 14 positives. The serum-marker
addition to ERIS does not significantly improve AUC. The fibrosis
nomogram beats familiar scores only inside the development data. The
bile-stone threshold is tied to a selected suspected population and a
composite reference standard. These details change whether a result is a
transport test, a screening hypothesis or an optimistic internal
estimate.
For implementation, preserve provenance at every layer: one row per
patient at splitting, site and time labels for transport, a prediction
landmark that precedes the decision, and nested feature selection. Treat
coded EHR phenotypes, pathology outcomes, composite reference tests and
post-treatment biomarkers as different measurement processes.
Prospective enrollment is not a prospective impact trial, and neither
retrospective discrimination nor engineering maintenance establishes
clinical benefit, privacy, regulatory approval or individual medical
advice.
News from major medical data and imaging developers
Developer and institutional releases
MedMLX publishes a coordinated Apple-Silicon imaging package wave without per-version accuracy evidence — 7 November 2026
The official package descriptions cover Apple-Silicon/Metal inference
for CT reporting and question answering, CT/CT-MR segmentation and
nnU-Net configurations including liver, pancreas and AutoPET.
mlx-reason-ct documents 17.4 GB of FP32 weights on disk,
keeps decoder weights in memory at their exact BF16 values and reports
about 14.4 GB peak MLX memory for a float32 chest or abdomen report. It
accepts NIfTI rather than DICOM and retains OpenMDW model terms; model
weights elsewhere retain their upstream licences. The release pages do
not document a clear accuracy or behavioural delta for every patch, and
PyPI files expose no provenance attestations. These are
research/education packages whose outputs require expert review, not
clinical-device validation. MedMLX on PyPI · medmlx 0.4.7 ·
mlx-reason-ct
0.4.1 · mlx-segment-ct
0.3.6 · nnunet-mlx
0.7.2
MONAI-Physio rebuilds CT registration alignment and reports owner-run speed gains — catch-up, 5 November 2026
Project MONAI released MONAI-Physio 2026.11.1. It rebuilds initial alignment as ITK point-set iterative closest point, restricts lung fitting to lung labels, fixes PCA units, intermittent surface-RMSE failures and stale cached outputs.
Read findings, evidence and limitations
In the owner’s engineering test, the new alignment beat the prior VTK
ICP on all 29 Duke-heart cases, ran in roughly 1–2 seconds rather than
8–14 seconds, and succeeded on lung cases where VTK ICP failed. This is
an engineering benchmark, not diagnostic or treatment-planning
validation. The Apache-2.0 package’s optional weights can have separate
restrictions, and the documentation explicitly limits the software to
research and visualisation. MONAI-Physio
2026.11.1 release · MONAI-Physio
documentation
BasisSimulator reduces simulated photon-counting CT ring artefacts in an owner benchmark — catch-up, 5 November 2026
MolloiLab released BasisSimulator.jl 0.16.3 with water-slab spectral flat-field calibration, smoother hardening dependence and a finer pile-up table for photon-counting CT detector-defect simulations. In the owner’s noise-free simulation, ring artefacts fell from as much as 168 HU to below 0.6 HU relative to an ideal detector.
Read findings, evidence and limitations
Realistic-defect results change; ideal-detector output does not. The
MIT-licensed code includes bundled BSD/Apache components. The result is
a simulation benchmark, not patient-data or clinical validation, and it
does not establish performance on a physical scanner. BasisSimulator.jl
0.16.3 release
dcmjs beta releases patch private blocks, binary search, multiframe views and logging — catch-up, 1–5 November 2026
The MIT-licensed dcmjs project released 1.0.0 beta.6 through beta.10. The train fixes private-block/prototype handling, adds a binary-search-backed SplitDataView, corrects zero-length string parsing, adds per-frame views of multiframe datasets and private macros, and removes InlineBinary debug logging.
Read findings, evidence and limitations
These are prerelease JavaScript DICOM-manipulation changes without a
published performance, interoperability or clinical benchmark. Deployers
should test the relevant transfer syntaxes, private data and multiframe
objects in their own workflows before adoption. dcmjs
releases
OHIF Viewer 3.13.14 is labelled security-focused but exposes no public vulnerability delta — catch-up, 3 November 2026
OHIF released Viewer 3.13.14 and described the update only as “all security focused,” pointing to its maintenance pull request. The public release does not name CVEs, affected components, behavioural changes or validation results.
Read findings, evidence and limitations
The MIT-licensed viewer remains available, but the sparse release
record supports only a maintenance/availability statement. It does not
justify claims about a specific corrected vulnerability,
interoperability, diagnostic accuracy or clinical benefit. OHIF Viewer
3.13.14
ER-REASON 1.1.0 adds structured diagnostic codes and script-concordance annotations under restricted access — catch-up, 2 November 2026
PhysioNet’s ER-REASON 1.1.0 covers 3,437 adults, 3,984 emergency encounters, 25,174 de-identified notes and 72 expert-written rationales. The release adds sct_reasoning.csv, sct_test.csv and structured icd10_codes.csv. Script-concordance-test annotations cover 194 encounters, produced by two board-certified emergency physicians with third-reviewer adjudication.
Read findings, evidence and limitations
Access requires PhysioNet credentialing, CITI training, a signed
Contributor Review Health Data License/DUA 1.5.0 and contributor project
review. Twenty encounters lack diagnosis codes and the value 1970 marks
missing dates. The dataset is for research, not clinical
decision-making, and no model-performance claim accompanies this
release. PhysioNet
TAIR releases CTA/MRA studies and fluoroscopy video while later segmentation remains pending — catch-up, 3–4 November 2026
Kitware and the University of North Carolina announced the initial TAIR multimodal cerebrovascular dataset: 500 combined CTA/MRA studies in NIfTI and 150 fluoroscopy videos in MP4, paired where available, approximately 70 GB and derived from multicentre routine critical-care imaging.
Read findings, evidence and limitations
The owners state that metadata were stripped of protected health
information and images were defaced or cleared of burned-in text. Access
is CC BY 4.0 without an AWS account. The release does not separate CT
from MR counts, provide a standard train/test split or include the 100
segmented models announced for a later phase. The portal also shows
inconsistent future “created/last update” fields, so the owner’s 4
November announcement is the more reliable availability date. TAIR
owner announcement · TAIR dataset
portal
A zebrafish micro-CT dataset supplies dense labels but its slice split cannot test specimen generalisation — catch-up, 6 November 2026
Penn State researchers released version 1 of a synchrotron whole-body micro-CT dataset from one fixed and stained zebrafish: 917 sagittal TIFF slices at 0.5-µm isotropic resolution with expert brain, heart and eye labels on every slice.
Read findings, evidence and limitations
The listed split is 733 training and 184 held-out slices; class
imbalance is documented. The dataset is CC BY 4.0. This is a single
nonhuman specimen. A random slice-level split shares anatomy and
preparation across training and test data, so it cannot measure
cross-specimen or clinical generalisation. No independent segmentation
benchmark accompanies the release. Mendeley
Data
Edition: 8 November 2026. Coverage cutoff: 8 November 2026, 05:02:03
UTC. The previous confirmed Medical Data cutoff was 7 November 2026,
05:02:53 UTC, so the strict interval was (2026-11-07T05:02:53Z,
2026-11-08T05:02:03Z]; the rolling catch-up began 1 November 2026,
05:02:53 UTC. Calendar-date 7 November publisher records were retained
conservatively because the publishers exposed no exact first-public time
or timezone and the records were absent from the prior Medical
ledger.
The research stream screened about 120 metadata/title/abstract
records, retained 12 strict-window peer-reviewed studies and excluded
one PET-dominant borderline record; no 30/90-day earlier-reading
backfill was needed. The release stream screened 19 candidate groups,
opened 15 primary records, retained one strict-window coordinated
package wave and seven rolling catch-up releases, held two records for
unresolved availability or predecessor-delta evidence, filtered five
already covered releases and excluded four others. No patient records,
CT/DICOM files, datasets, model weights, binaries or archives were
downloaded.
Research coverage included PubMed and Europe PMC discovery, arXiv,
medRxiv, MICCAI, MIDL/MLHC, Elsevier/Medical Image Analysis, Springer
Nature/BMC, IEEE, RSNA, Wiley, ACM, Taylor & Francis, SAGE, OUP,
Cambridge, AAAS, PNAS, PLOS, Frontiers, MDPI, Royal Society and IOP.
Release coverage included official TCIA, IDC, EUCAIM, PhysioNet, MONAI,
OHIF, SimpleITK, Orthanc/DICOM tooling, package registries,
institutional repositories and major imaging-vendor surfaces. Web of
Science and Scopus were unavailable without authorised access;
PubMed/Europe PMC had a future-date indexing mismatch; IOP blocked
automated retrieval; some Frontiers/Dove records were accessible only
through primary journal indexes or abstracts; Elsevier full text was
paywalled; Hugging Face pagination and EUCAIM chronology were
incomplete. These are coverage limitations, not evidence of no other
activity.
Verification: two independent source checks passed; experiments were
not independently reproduced.