External validation only counts when it remains outside the model-selection loop
Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.
Daily briefing · 10 November 2026
Today’s evidence turns on a basic but consequential distinction: a
cohort can be geographically external without being statistically
untouched. A four-centre hepatocellular-carcinoma study reports an
external C-index of 0.740 for a clinical–CT radiomics model, yet
selected the winning pipeline using average performance across training,
internal-validation and external cohorts. That makes the external set
part of model selection. By contrast, a kidney-progression study
explicitly repeated feature selection inside cross-validation and showed
how apparent AUC fell when optimism was controlled.
The wider record shows several more useful stress tests. A PET/CT
habitat model carried a training-selected decision threshold into an
independent centre. In the lung subsolid-nodule study, thresholds were
also fixed from training, but all seven algorithms were evaluated in the
external centre before RF was finalized, so that cohort is not a fully
untouched test for the deployed RF model. Surgical-spectrum selection
and limited negative predictive value further constrain clinical
interpretation. A cardiac-CT Transformer transported across institutions
but predicts historical operator use of atherectomy rather than
appropriateness or outcomes.
For researchers and builders, the practical rule is to treat
validation design as part of the reported result. Keep external cohorts
out of feature, pipeline and threshold selection; split repeated lesions
at patient level; preserve centre-held-out tests; and report
calibration, simple baselines and clinically relevant endpoints.
Retrospective discrimination can justify further validation, but it does
not establish patient benefit, molecular diagnosis, regulatory approval
or safe deployment.
A four-centre HCC CT model uses its nominal external cohort during pipeline selection — 10 November 2026
Shuyao Ning and colleagues studied pretreatment arterial- and portal-venous-phase contrast-enhanced CT in 180 patients with unresectable hepatocellular carcinoma treated with TACE plus immunotherapy and targeted therapy. The retrospective four-centre split comprised 93 training, 39 internal-validation and 48 external-centre patients.
Read findings, evidence and limitations
Shuyao Ning and colleagues studied pretreatment arterial- and
portal-venous-phase contrast-enhanced CT in 180 patients with
unresectable hepatocellular carcinoma treated with TACE plus
immunotherapy and targeted therapy. The retrospective four-centre split
comprised 93 training, 39 internal-validation and 48 external-centre
patients. From 2,153 features per phase, the team constructed a
six-feature radiomics score and combined it with HBV infection and
vascular invasion for overall-survival prediction.
The selected LASSO-Cox plus random-survival-forest pipeline achieved
C-indices of 0.893, 0.758 and 0.740 in the training, internal and
external cohorts; external one-, two- and three-year AUCs were 0.731,
0.700 and 0.756. The important limitation is procedural: after
evaluating 97 pipelines, the authors selected the winner by the average
C-index across all three cohorts. The external cohort therefore informed
model choice and cannot support an untouched external-performance claim.
The external sample was small, the population was predominantly male and
HBV-positive, and no prospective impact test was performed. Scientific
Reports paper.
Nested feature selection exposes optimism in three-month kidney-progression prediction — 9 November 2026
Mehmet Erdem and Ozan Aydemir evaluated 52 routine baseline clinical and laboratory variables in 382 single-centre patients with type 2 diabetes; 162 met a three-month KDIGO-based progression endpoint. Seven algorithms were evaluated with repeated stratified five-fold cross-validation. An initial LASSO screen retained 22 predictors.
Read findings, evidence and limitations
Mehmet Erdem and Ozan Aydemir evaluated 52 routine baseline clinical
and laboratory variables in 382 single-centre patients with type 2
diabetes; 162 met a three-month KDIGO-based progression endpoint. Seven
algorithms were evaluated with repeated stratified five-fold
cross-validation. An initial LASSO screen retained 22 predictors.
When feature selection preceded cross-validation, SVM and LASSO
logistic regression reached AUCs of 0.682 and 0.671. Repeating selection
inside the training folds reduced them to 0.603 and 0.640. For LASSO
logistic regression, sensitivity, specificity, PPV and NPV were 0.648,
0.650, 0.577 and 0.715; Platt-scaled Brier score was 0.225 and
calibration slope 1.39. The contribution is the quantified optimism
check, not a deployment-ready risk tool: there was no external cohort,
the horizon was short and discrimination remained modest. Frontiers
in Endocrinology paper.
A beta-lactam allergy classifier validates temporally but remains single-centre and label-dependent — 10 November 2026
Sima Bahrami and colleagues trained structured-history classifiers on 322 Iranian allergy-clinic records with nine variables, then applied the models without retraining or retuning to an independent same-centre temporal cohort of 80. Random forest performance was reported as 0.90 accuracy, 0.90 sensitivity, 0.89 specificity, 0.90 F1 and 0.97 AUC internally, rising to 0.96/0.95/0.98/0.96/0.99 temporally.
Read findings, evidence and limitations
Sima Bahrami and colleagues trained structured-history classifiers on
322 Iranian allergy-clinic records with nine variables, then applied the
models without retraining or retuning to an independent same-centre
temporal cohort of 80. Random forest performance was reported as 0.90
accuracy, 0.90 sensitivity, 0.89 specificity, 0.90 F1 and 0.97 AUC
internally, rising to 0.96/0.95/0.98/0.96/0.99 temporally.
The temporal test is useful, but it does not establish geographic or
workflow transport. The balanced research dataset differs from routine
prevalence, cohorts were small, and the surfaced methods do not show
uniform drug-provocation confirmation for every patient. Because history
variables also inform the clinical reference diagnosis, incorporation
bias remains possible. Scientific
Reports paper.
Pooled-centre random splitting limits a high-AUC clinical OSA model — 9 November 2026
Neslihan Özçelik and colleagues pooled 1,954 adults from ten sleep centres and used 18 demographic and clinical variables to predict polysomnography-defined obstructive-sleep-apnoea severity. A one-hidden-layer neural network was evaluated on a random 80/20 split and reported class AUCs of 0.89–0.96 across no, mild, moderate and severe OSA.
Read findings, evidence and limitations
Neslihan Özçelik and colleagues pooled 1,954 adults from ten sleep
centres and used 18 demographic and clinical variables to predict
polysomnography-defined obstructive-sleep-apnoea severity. A
one-hidden-layer neural network was evaluated on a random 80/20 split
and reported class AUCs of 0.89–0.96 across no, mild, moderate and
severe OSA.
The contribution is a comparatively large multicentre structured
dataset, but centre was not held out: referral patterns and
centre-specific measurement practices can therefore appear in both train
and test. The abstract does not establish calibration, comparison with
simpler screening questionnaires or independent transport. The results
support centre-held-out testing, not replacement of polysomnography. Scientific
Reports paper.
ECG and natriuretic peptides add derivation signal to an echo-led PH model — 9 November 2026
Yanwei Gao and colleagues combined echocardiographic pulmonary-artery systolic pressure with structured ECG and BNP/NT-proBNP positivity in 130 patients referred for right-heart catheterisation, then tested the fixed model in 42 later patients from the same centre. The endpoint was mean pulmonary-artery pressure above 20 mmHg at catheterisation.
Read findings, evidence and limitations
Yanwei Gao and colleagues combined echocardiographic pulmonary-artery
systolic pressure with structured ECG and BNP/NT-proBNP positivity in
130 patients referred for right-heart catheterisation, then tested the
fixed model in 42 later patients from the same centre. The endpoint was
mean pulmonary-artery pressure above 20 mmHg at catheterisation.
Derivation AUC was 0.825 versus 0.730 for echo pressure alone (DeLong
p=0.008), with bootstrap optimism-corrected AUC 0.811. Temporal AUC was
0.792 versus 0.749, and the difference was not significant. The small,
highly imbalanced, referral-conditioned cohorts and absence of external
validation limit generalisation; the model is not interchangeable with
invasive haemodynamic measurement. Cardiovascular
Ultrasound paper.
An endodontic CT model loses discrimination temporally and does not outperform clinicians — 9 November 2026
Sheng Feng and colleagues used 26 peri- and postoperative candidates, including cone-beam CT bone-loss volume, to predict one-year healing after endodontic microsurgery. Development included 312 patients, split into 218 training and 94 internal-selection cases; a later 108-patient cohort contained only 13 failures. L2 logistic regression was selected after training-set feature selection.
Read findings, evidence and limitations
Sheng Feng and colleagues used 26 peri- and postoperative candidates,
including cone-beam CT bone-loss volume, to predict one-year healing
after endodontic microsurgery. Development included 312 patients, split
into 218 training and 94 internal-selection cases; a later 108-patient
cohort contained only 13 failures. L2 logistic regression was selected
after training-set feature selection.
AUC was 0.812 in out-of-fold training, 0.868 in internal selection
and 0.703 in the temporal cohort (95% CI 0.530–0.867). Temporal
calibration intercept and slope were 1.11 and 0.54. The model’s temporal
AUC of 0.696 in the clinician-comparison analysis did not exceed the
pooled clinicians’ 0.771 (difference −0.075, p=0.186). Postoperative
predictors also prevent preoperative use. Scientific
Reports paper.
A dual-centre lung-nodule study reports high external AUC but uses that cohort in final model choice — 3 November 2026 catch-up
Lilan She and colleagues combined commercial AI-derived CT measurements with radiologist semantic features in 833 patients with surgically resected, pathology-confirmed subsolid nodules. Development used 586 cases and an external centre supplied 247; feature selection occurred on training data and thresholds were fixed before external testing. The endpoint was invasive adenocarcinoma versus AAH, AIS or MIA.
Read findings, evidence and limitations
Lilan She and colleagues combined commercial AI-derived CT
measurements with radiologist semantic features in 833 patients with
surgically resected, pathology-confirmed subsolid nodules. Development
used 586 cases and an external centre supplied 247; feature selection
occurred on training data and thresholds were fixed before external
testing. The endpoint was invasive adenocarcinoma versus AAH, AIS or
MIA.
Internal repeated-cross-validation AUCs were 0.935–0.940, while
external random-forest AUC was 0.959 (95% CI 0.938–0.980). External
XGBoost accuracy, sensitivity and F1 were 0.874, 0.900 and 0.853.
However, all seven candidate algorithms were evaluated in the external
cohort before RF was finalized, so that cohort is not a fully untouched
test of the deployed RF model. The cross-centre performance is
encouraging for the measured surgical population, but benign and
surveillance-managed nodules were excluded, creating verification and
spectrum bias; portability also depends on commercial feature
extraction. Frontiers
in Oncology paper.
PET/CT habitat radiomics predicts EGFR status as an adjunct, not a molecular test — 7 November 2026 catch-up
Haoran Lian and colleagues analysed 313 patients with locally advanced non-small-cell lung cancer. One centre supplied 142 training and 61 internal-validation cases; a second supplied 110 external cases. Voxel-wise PET and CT thresholds formed four intersected habitats, six classifiers were compared, and the decision threshold was fixed from training data.
Read findings, evidence and limitations
Haoran Lian and colleagues analysed 313 patients with locally
advanced non-small-cell lung cancer. One centre supplied 142 training
and 61 internal-validation cases; a second supplied 110 external cases.
Voxel-wise PET and CT thresholds formed four intersected habitats, six
classifiers were compared, and the decision threshold was fixed from
training data. Tissue testing defined EGFR mutation status.
The SVM habitat model reported AUCs of 0.911, 0.898 and 0.884 across
training, internal and external cohorts; a combined model reached
external AUC 0.904. External sensitivity, specificity, accuracy and NPV
were 0.750, 0.739, 0.745 and 0.680. The independent-centre result
supports prospective study, but the NPV is insufficient to rule out
mutation and the retrospective model cannot replace tissue or plasma
molecular testing. PubMed record.
A cardiac-CT Transformer predicts atherectomy use, not clinical necessity — 5 November 2026 catch-up
Rissei Hino and colleagues trained a ConvNeXt-plus-Transformer multiple-instance model on 498 calcified lesions from 419 patients. Twelve institutions supplied four-fold development data; two independent institutions supplied 97 external lesions. A training-derived threshold was applied unchanged.
Read findings, evidence and limitations
Rissei Hino and colleagues trained a ConvNeXt-plus-Transformer
multiple-instance model on 498 calcified lesions from 419 patients.
Twelve institutions supplied four-fold development data; two independent
institutions supplied 97 external lesions. A training-derived threshold
was applied unchanged. External AUC was 0.788 from CCTA alone and 0.805
after adding seven clinical variables.
External accuracy was 0.742, compared with 0.619 for general
cardiologists (p=0.029) and 0.670 for PCI experts (p=0.230). The
endpoint was operators’ historical atherectomy use, not procedural
appropriateness or patient outcome. Development folds were lesion-level;
because some patients contributed multiple lesions, the surfaced methods
do not rule out same-patient leakage across folds. European
Heart Journal – Digital Health paper.
CT-to-BMD ensemble complexity does not significantly beat the best single model — 5 November 2026 catch-up
Satoru Tanioka and colleagues compared simple HU regression, radiomics, CNN and ensemble estimation of DXA bone mineral density using four hospitals. T12 analysis included 465 patients and L1 included 448; two institutions were reserved for external testing. At T12, the ensemble’s MAE/RMSE/R² were 0.128/0.154/0.620 versus 0.122/0.157/0.603 for the CNN.
Read findings, evidence and limitations
Satoru Tanioka and colleagues compared simple HU regression,
radiomics, CNN and ensemble estimation of DXA bone mineral density using
four hospitals. T12 analysis included 465 patients and L1 included 448;
two institutions were reserved for external testing. At T12, the
ensemble’s MAE/RMSE/R² were 0.128/0.154/0.620 versus 0.122/0.157/0.603
for the CNN. At L1, the ensemble achieved 0.116/0.145/0.633 versus
0.124/0.155/0.582 for radiomics.
Absolute-error differences from the best single model were not
significant. The study’s contribution is the controlled comparison and
institution-level external test, not an ensemble-win claim. The abstract
does not expose exact site counts or scanner-protocol transport details,
and clinical osteoporosis thresholds or impact were not evaluated. PubMed record.
A CT xerostomia review finds wide AUCs but only moderate methodological quality — 9 November 2026
Nicola Jones-Anderson and colleagues reviewed 22 studies with cohorts from 19 to 1,208 patients; 14 used CT. Endpoints varied across clinician grading, patient reports and salivary output. Reported CT AUCs ranged from 0.64 to 0.93, and delta-radiomics studies reported 0.86–0.93, but mean Radiomics Quality Score was only 14/36.
Read findings, evidence and limitations
Nicola Jones-Anderson and colleagues reviewed 22 studies with cohorts
from 19 to 1,208 patients; 14 used CT. Endpoints varied across clinician
grading, patient reports and salivary output. Reported CT AUCs ranged
from 0.64 to 0.93, and delta-radiomics studies reported 0.86–0.93, but
mean Radiomics Quality Score was only 14/36.
The review argues that limited external validation, absent
prospective work, weak open-science practice and missing
cost-effectiveness analysis prevent routine clinical readiness. It is a
structured narrative review rather than a meta-analysis, so
heterogeneous endpoints and designs preclude a pooled performance
estimate. Cambridge
University Press review.
A small CT preprint localises cochlear landmarks with at most 16 training volumes — posted 8 November 2026
Yifan Wang and colleagues describe MEDICO-YOLO for six cochlear landmarks total—apex, basal point and round-window centre in each cochlea—in 0.3-mm preoperative CT. Training experiments used 4, 8, 12 or 16 volumes and testing used 16. The abstract reports mean error of 1.30 mm with eight training volumes and 0.71 mm with 16, plus 97.92% success within 3 mm and 25.43-second whole-volume latency on an Apple M1.
Read findings, evidence and limitations
Yifan Wang and colleagues describe MEDICO-YOLO for six cochlear
landmarks total—apex, basal point and round-window centre in each
cochlea—in 0.3-mm preoperative CT. Training experiments used 4, 8, 12 or
16 volumes and testing used 16. The abstract reports mean error of 1.30
mm with eight training volumes and 0.71 mm with 16, plus 97.92% success
within 3 mm and 25.43-second whole-volume latency on an Apple M1.
This is a non-peer-reviewed medRxiv preprint with extremely small
samples, no external centre or device validation, and uncertain
confidence around the reported estimates. It is best treated as a
feasibility signal, not a clinical localisation result. medRxiv DOI.
Across the studies, validation labels are less informative than data
flow. An “external” cohort cannot support independent validation if it
helped select one of 97 pipelines. A multicentre pool does not
demonstrate transport when centres are mixed across a random split. A
lesion-level cross-validation scheme may still leak patient-specific
information when patients contribute multiple lesions. Centre-held-out
tests and training-fixed thresholds strengthen evidence only when
feature, algorithm and threshold choices are all locked before
evaluation.
Three reporting upgrades would make these studies easier to use.
First, publish a complete selection graph showing where imputation,
harmonisation, feature selection, model choice and threshold choice were
fitted. Second, report simple baselines, calibration and clinically
interpretable operating points alongside AUC or C-index. Third, name the
endpoint precisely: historical device use is not appropriateness,
molecular-probability estimation is not genotyping, and retrospective
survival discrimination is not improved survival.
News from major medical data and imaging developers
News from major medical data and imaging developers
TCIA advances LDCT-and-Projection-data to Version 8 without documenting a substantive delta — 9 November 2026
The Cancer Imaging Archive now lists Version 8 of its matched routine-dose and simulated lower-dose CT collection with raw projections, acquisition geometry and reconstructed images. The catalogue covers 299 cases: 99 head, 100 chest and 100 abdomen/liver.
Read findings, evidence and limitations
The Cancer Imaging Archive now lists Version 8 of its matched
routine-dose and simulated lower-dose CT collection with raw
projections, acquisition geometry and reconstructed images. The
catalogue covers 299 cases: 99 head, 100 chest and 100 abdomen/liver.
Current tables list 99 chest subjects with 2,267,266 images, 100 liver
subjects with 5,759,639 images, 99 head subjects with 4,968,595 images
and one phantom with 18,032 images, totalling about 1.29 TB.
Chest, liver and phantom data are CC BY 4.0; head data require NIH
controlled access because facial reconstruction may be possible. The
DICOM-CT-PD dictionary and reader are CC BY 3.0. The official Version 8
changelog is empty, so this edition does not claim new scans, a
reconstruction benchmark or a specific v7-to-v8 data delta. No files
were retrieved. TCIA
collection.
News from major medical data and imaging developers
MedMLX publishes lesiondiffusion-mlx 0.2.8 for 3D CT lesion synthesis — 9 November 2026 catch-up
MedMLX’s Apple-Silicon package accepts a CT NIfTI volume in Hounsfield units plus an aligned organ mask and outputs a synthetic CT and lesion mask. Controls cover organ, lesion type, bounding box, text phenotype, diffusion steps and seed; regional output modes can blend a box or lesion-local neighbourhood while retaining the raw synthetic result.
Read findings, evidence and limitations
MedMLX’s Apple-Silicon package accepts a CT NIfTI volume in
Hounsfield units plus an aligned organ mask and outputs a synthetic CT
and lesion mask. Controls cover organ, lesion type, bounding box, text
phenotype, diffusion steps and seed; regional output modes can blend a
box or lesion-local neighbourhood while retaining the raw synthetic
result. The current card reports peak memory of 5.19 GB in conditioned
mode and 3.46 GB in source mode for one 160×160×128 AMOS crop at 200
steps.
Those are single-case engineering measurements, not clinical or
detection results. The card warns that lesions may extend beyond
requested bounds and non-lesion attenuation can shift. Version 0.2.8 has
no located version-specific changelog, so the incremental change from
the previously covered 0.2.7 release is unresolved. The beta package is
Apache-2.0 with MIT/BSD components; separately downloaded weights keep
their own terms. PyPI
release.
News from major medical data and imaging developers
eehrxf 0.3.0 maps EHDS-oriented openEHR and FHIR structures with provenance hooks — 9 November 2026
Cadasto/FerroHEALTH’s Rust crate reads Xt-EHR logical information models for patient summaries, prescriptions, dispensations, imaging, laboratory and discharge data; maps between openEHR canonical JSON and FHIR R4; and can retain incoming originals in FEEDER_AUDIT.
Read findings, evidence and limitations
Cadasto/FerroHEALTH’s Rust crate reads Xt-EHR logical information
models for patient summaries, prescriptions, dispensations, imaging,
laboratory and discharge data; maps between openEHR canonical JSON and
FHIR R4; and can retain incoming originals in FEEDER_AUDIT.
Its documentation describes validation of bundle/profile constraints,
cardinalities, slices and fixed values, plus terminology checks for
SNOMED CT, LOINC, ICD-10 and FHIR services.
docs.rs reports 233/233 public items documented, but this is
documentation coverage rather than interoperability validation; the
owner reports no hospital cohort, interoperability event,
conformance-suite result or error-rate study. The rapid same-day version
train has no human-readable 0.3.0 changelog. BSL 1.1 permits
non-production and non-commercial production use; other production use
needs a commercial licence, with an Apache-2.0 change after four years.
eehrxf
documentation.
News from major medical data and imaging developers
FerroHEALTH’s 0.10.0 audit stack links DICOM/IHE transport to EHDS logging categories — 9 November 2026
The coordinated ihe-atna and ehds-logging crates implement DICOM PS3.15 audit messages over RFC 5424/5425 syslog with TLS, bounded store-and-forward, retry, quarantine and redaction; FHIR R4 BALP AuditEvent transport; and mappings to EHDS access categories. The logging documentation references six priority categories from the HL7 Europe health-data-api ballot.
Read findings, evidence and limitations
The coordinated ihe-atna and ehds-logging
crates implement DICOM PS3.15 audit messages over RFC 5424/5425 syslog
with TLS, bounded store-and-forward, retry, quarantine and redaction;
FHIR R4 BALP AuditEvent transport; and mappings to EHDS access
categories. The logging documentation references six priority categories
from the HL7 Europe health-data-api ballot.
This is implementation documentation, not proof of production
privacy, IHE conformance or EHDS compliance. No independent conformance
result, penetration test, event-volume benchmark or hospital deployment
was reported, and deployers still control mappings, certificates,
retention and jurisdictional requirements. Both crates use the same BSL
1.1 production restrictions and four-year Apache conversion. ihe-atna · ehds-logging.
News from major medical data and imaging developers
IsiX DICOM Viewer 6.0.0-beta4 adds cross-study pan synchronisation and expands migration and diagnostic handling — 10 November 2026
Thales Santos’s macOS pre-release adds locked-study pan propagation, expands support and plug-in migration for Horos-era installations, improves DICOM-print log handling, and reports idle DICOM associations more clearly. The release continues the beta line’s diagnostic and workflow work rather than presenting a clinical algorithm.
Read findings, evidence and limitations
Thales Santos’s macOS pre-release adds locked-study pan propagation,
expands support and plug-in migration for Horos-era installations,
improves DICOM-print log handling, and reports idle DICOM associations
more clearly. The release continues the beta line’s diagnostic and
workflow work rather than presenting a clinical algorithm.
The owner reports focused tests, but there is no clinical-accuracy,
inter-reader, external-conformance or performance study. The software is
a beta, requires macOS 15+, and its source is LGPL-3.0 while branding is
separately reserved. GitHub
beta4 release.
News from major medical data and imaging developers
CodePawl converts seven CT-derived bodies into compact GLB anatomy assets — 4–7 November 2026 catch-up
CodePawl’s CC BY 4.0 dataset contains 27 assets: seven real CT-derived bodies and 20 organ or system models, with up to 115 named structures per body and several levels of detail. The pipeline converts TotalSegmentator v2.0.1 masks into smoothed and decimated meshes. The card reports 2,515,782 final triangles from 20,238,966 raw triangles and a 20.07 MB body/organ package.
Read findings, evidence and limitations
CodePawl’s CC BY 4.0 dataset contains 27 assets: seven real
CT-derived bodies and 20 organ or system models, with up to 115 named
structures per body and several levels of detail. The pipeline converts
TotalSegmentator v2.0.1 masks into smoothed and decimated meshes. The
card reports 2,515,782 final triangles from 20,238,966 raw triangles and
a 20.07 MB body/organ package.
The seven cases span ages 31–94 and include two men and five women.
Import and orientation checks were owner-run in three.js, Blender and
Unreal; no geometric error, segmentation Dice or clinical review was
reported. Small structures are simplified, some extremities are absent,
and source-segmentation errors propagate. The resource is for
visualisation and education, not diagnosis. Hugging
Face dataset card.
The strict interval was after 9 November 2026 06:08:15 UTC through 10
November 2026 06:13:56 UTC, with a rolling seven-day catch-up from 3
November 2026 06:13:56 UTC. The Medical Data ledger contained 110
previously covered story URLs or identifiers from 5–9 November; none of
the 18 reported research and release records matched it. The research
stream retained 11 peer-reviewed records plus one small CT preprint, and
the official-release stream retained six records. Lower-value,
out-of-scope, older-by-true-date, previously covered and insufficiently
documented records were excluded.
PubMed, medRxiv, arXiv, MICCAI/MIDL/MLHC discovery, publisher
families and official developer/institution sources were checked. No
genuinely date-new MIDL, MLHC or MICCAI proceeding and no clearly
eligible strict-window arXiv paper were found. Web of Science and Scopus
were unavailable, so neither was queried. No 30/90-day publisher
backfill was used because current and seven-day journal coverage was
sufficient. Direct Elsevier, IEEE and RSNA families were preserved in
discovery even though no new eligible article was retained from some
families.
Several publisher and catalogue pages expose only calendar dates, so
those records remain date-level candidates. Registry and release APIs
that expose exact UTC timestamps—including PyPI, crates.io and
GitHub—were adjudicated directly against the cutoffs. Access failure or
an empty changelog was not treated as evidence of no activity;
unsupported version deltas were omitted. No patient-level records,
CT/DICOM files, masks, model weights, meshes or release binaries were
retrieved.
Verification: two independent source checks passed; experiments were
not independently reproduced.