Daily briefings
ATLAS

Research. Knowledge. Opportunity.
A clearer view of what comes next.

External validation only counts when it remains outside the model-selection loop

Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.

Daily briefing · 10 November 2026

Today’s evidence turns on a basic but consequential distinction: a cohort can be geographically external without being statistically untouched. A four-centre hepatocellular-carcinoma study reports an external C-index of 0.740 for a clinical–CT radiomics model, yet selected the winning pipeline using average performance across training, internal-validation and external cohorts. That makes the external set part of model selection. By contrast, a kidney-progression study explicitly repeated feature selection inside cross-validation and showed how apparent AUC fell when optimism was controlled.

The wider record shows several more useful stress tests. A PET/CT habitat model carried a training-selected decision threshold into an independent centre. In the lung subsolid-nodule study, thresholds were also fixed from training, but all seven algorithms were evaluated in the external centre before RF was finalized, so that cohort is not a fully untouched test for the deployed RF model. Surgical-spectrum selection and limited negative predictive value further constrain clinical interpretation. A cardiac-CT Transformer transported across institutions but predicts historical operator use of atherectomy rather than appropriateness or outcomes.

For researchers and builders, the practical rule is to treat validation design as part of the reported result. Keep external cohorts out of feature, pipeline and threshold selection; split repeated lesions at patient level; preserve centre-held-out tests; and report calibration, simple baselines and clinically relevant endpoints. Retrospective discrimination can justify further validation, but it does not establish patient benefit, molecular diagnosis, regulatory approval or safe deployment.

Edition links

Medical Data desk · 10 November 2026 briefing · Medical Data briefing archive

Peer-reviewed research

A four-centre HCC CT model uses its nominal external cohort during pipeline selection — 10 November 2026

Shuyao Ning and colleagues studied pretreatment arterial- and portal-venous-phase contrast-enhanced CT in 180 patients with unresectable hepatocellular carcinoma treated with TACE plus immunotherapy and targeted therapy. The retrospective four-centre split comprised 93 training, 39 internal-validation and 48 external-centre patients.

Read findings, evidence and limitations

Shuyao Ning and colleagues studied pretreatment arterial- and portal-venous-phase contrast-enhanced CT in 180 patients with unresectable hepatocellular carcinoma treated with TACE plus immunotherapy and targeted therapy. The retrospective four-centre split comprised 93 training, 39 internal-validation and 48 external-centre patients. From 2,153 features per phase, the team constructed a six-feature radiomics score and combined it with HBV infection and vascular invasion for overall-survival prediction.

The selected LASSO-Cox plus random-survival-forest pipeline achieved C-indices of 0.893, 0.758 and 0.740 in the training, internal and external cohorts; external one-, two- and three-year AUCs were 0.731, 0.700 and 0.756. The important limitation is procedural: after evaluating 97 pipelines, the authors selected the winner by the average C-index across all three cohorts. The external cohort therefore informed model choice and cannot support an untouched external-performance claim. The external sample was small, the population was predominantly male and HBV-positive, and no prospective impact test was performed. Scientific Reports paper.

Read the source · Scientific Reports paper

Nested feature selection exposes optimism in three-month kidney-progression prediction — 9 November 2026

Mehmet Erdem and Ozan Aydemir evaluated 52 routine baseline clinical and laboratory variables in 382 single-centre patients with type 2 diabetes; 162 met a three-month KDIGO-based progression endpoint. Seven algorithms were evaluated with repeated stratified five-fold cross-validation. An initial LASSO screen retained 22 predictors.

Read findings, evidence and limitations

Mehmet Erdem and Ozan Aydemir evaluated 52 routine baseline clinical and laboratory variables in 382 single-centre patients with type 2 diabetes; 162 met a three-month KDIGO-based progression endpoint. Seven algorithms were evaluated with repeated stratified five-fold cross-validation. An initial LASSO screen retained 22 predictors.

When feature selection preceded cross-validation, SVM and LASSO logistic regression reached AUCs of 0.682 and 0.671. Repeating selection inside the training folds reduced them to 0.603 and 0.640. For LASSO logistic regression, sensitivity, specificity, PPV and NPV were 0.648, 0.650, 0.577 and 0.715; Platt-scaled Brier score was 0.225 and calibration slope 1.39. The contribution is the quantified optimism check, not a deployment-ready risk tool: there was no external cohort, the horizon was short and discrimination remained modest. Frontiers in Endocrinology paper.

Read the source · Frontiers in Endocrinology paper

A beta-lactam allergy classifier validates temporally but remains single-centre and label-dependent — 10 November 2026

Sima Bahrami and colleagues trained structured-history classifiers on 322 Iranian allergy-clinic records with nine variables, then applied the models without retraining or retuning to an independent same-centre temporal cohort of 80. Random forest performance was reported as 0.90 accuracy, 0.90 sensitivity, 0.89 specificity, 0.90 F1 and 0.97 AUC internally, rising to 0.96/0.95/0.98/0.96/0.99 temporally.

Read findings, evidence and limitations

Sima Bahrami and colleagues trained structured-history classifiers on 322 Iranian allergy-clinic records with nine variables, then applied the models without retraining or retuning to an independent same-centre temporal cohort of 80. Random forest performance was reported as 0.90 accuracy, 0.90 sensitivity, 0.89 specificity, 0.90 F1 and 0.97 AUC internally, rising to 0.96/0.95/0.98/0.96/0.99 temporally.

The temporal test is useful, but it does not establish geographic or workflow transport. The balanced research dataset differs from routine prevalence, cohorts were small, and the surfaced methods do not show uniform drug-provocation confirmation for every patient. Because history variables also inform the clinical reference diagnosis, incorporation bias remains possible. Scientific Reports paper.

Read the source · Scientific Reports paper

Pooled-centre random splitting limits a high-AUC clinical OSA model — 9 November 2026

Neslihan Özçelik and colleagues pooled 1,954 adults from ten sleep centres and used 18 demographic and clinical variables to predict polysomnography-defined obstructive-sleep-apnoea severity. A one-hidden-layer neural network was evaluated on a random 80/20 split and reported class AUCs of 0.89–0.96 across no, mild, moderate and severe OSA.

Read findings, evidence and limitations

Neslihan Özçelik and colleagues pooled 1,954 adults from ten sleep centres and used 18 demographic and clinical variables to predict polysomnography-defined obstructive-sleep-apnoea severity. A one-hidden-layer neural network was evaluated on a random 80/20 split and reported class AUCs of 0.89–0.96 across no, mild, moderate and severe OSA.

The contribution is a comparatively large multicentre structured dataset, but centre was not held out: referral patterns and centre-specific measurement practices can therefore appear in both train and test. The abstract does not establish calibration, comparison with simpler screening questionnaires or independent transport. The results support centre-held-out testing, not replacement of polysomnography. Scientific Reports paper.

Read the source · Scientific Reports paper

ECG and natriuretic peptides add derivation signal to an echo-led PH model — 9 November 2026

Yanwei Gao and colleagues combined echocardiographic pulmonary-artery systolic pressure with structured ECG and BNP/NT-proBNP positivity in 130 patients referred for right-heart catheterisation, then tested the fixed model in 42 later patients from the same centre. The endpoint was mean pulmonary-artery pressure above 20 mmHg at catheterisation.

Read findings, evidence and limitations

Yanwei Gao and colleagues combined echocardiographic pulmonary-artery systolic pressure with structured ECG and BNP/NT-proBNP positivity in 130 patients referred for right-heart catheterisation, then tested the fixed model in 42 later patients from the same centre. The endpoint was mean pulmonary-artery pressure above 20 mmHg at catheterisation.

Derivation AUC was 0.825 versus 0.730 for echo pressure alone (DeLong p=0.008), with bootstrap optimism-corrected AUC 0.811. Temporal AUC was 0.792 versus 0.749, and the difference was not significant. The small, highly imbalanced, referral-conditioned cohorts and absence of external validation limit generalisation; the model is not interchangeable with invasive haemodynamic measurement. Cardiovascular Ultrasound paper.

Read the source · Cardiovascular Ultrasound paper

An endodontic CT model loses discrimination temporally and does not outperform clinicians — 9 November 2026

Sheng Feng and colleagues used 26 peri- and postoperative candidates, including cone-beam CT bone-loss volume, to predict one-year healing after endodontic microsurgery. Development included 312 patients, split into 218 training and 94 internal-selection cases; a later 108-patient cohort contained only 13 failures. L2 logistic regression was selected after training-set feature selection.

Read findings, evidence and limitations

Sheng Feng and colleagues used 26 peri- and postoperative candidates, including cone-beam CT bone-loss volume, to predict one-year healing after endodontic microsurgery. Development included 312 patients, split into 218 training and 94 internal-selection cases; a later 108-patient cohort contained only 13 failures. L2 logistic regression was selected after training-set feature selection.

AUC was 0.812 in out-of-fold training, 0.868 in internal selection and 0.703 in the temporal cohort (95% CI 0.530–0.867). Temporal calibration intercept and slope were 1.11 and 0.54. The model’s temporal AUC of 0.696 in the clinician-comparison analysis did not exceed the pooled clinicians’ 0.771 (difference −0.075, p=0.186). Postoperative predictors also prevent preoperative use. Scientific Reports paper.

Read the source · Scientific Reports paper

Other new and catch-up findings

A dual-centre lung-nodule study reports high external AUC but uses that cohort in final model choice — 3 November 2026 catch-up

Lilan She and colleagues combined commercial AI-derived CT measurements with radiologist semantic features in 833 patients with surgically resected, pathology-confirmed subsolid nodules. Development used 586 cases and an external centre supplied 247; feature selection occurred on training data and thresholds were fixed before external testing. The endpoint was invasive adenocarcinoma versus AAH, AIS or MIA.

Read findings, evidence and limitations

Lilan She and colleagues combined commercial AI-derived CT measurements with radiologist semantic features in 833 patients with surgically resected, pathology-confirmed subsolid nodules. Development used 586 cases and an external centre supplied 247; feature selection occurred on training data and thresholds were fixed before external testing. The endpoint was invasive adenocarcinoma versus AAH, AIS or MIA.

Internal repeated-cross-validation AUCs were 0.935–0.940, while external random-forest AUC was 0.959 (95% CI 0.938–0.980). External XGBoost accuracy, sensitivity and F1 were 0.874, 0.900 and 0.853. However, all seven candidate algorithms were evaluated in the external cohort before RF was finalized, so that cohort is not a fully untouched test of the deployed RF model. The cross-centre performance is encouraging for the measured surgical population, but benign and surveillance-managed nodules were excluded, creating verification and spectrum bias; portability also depends on commercial feature extraction. Frontiers in Oncology paper.

Read the source · Frontiers in Oncology paper

PET/CT habitat radiomics predicts EGFR status as an adjunct, not a molecular test — 7 November 2026 catch-up

Haoran Lian and colleagues analysed 313 patients with locally advanced non-small-cell lung cancer. One centre supplied 142 training and 61 internal-validation cases; a second supplied 110 external cases. Voxel-wise PET and CT thresholds formed four intersected habitats, six classifiers were compared, and the decision threshold was fixed from training data.

Read findings, evidence and limitations

Haoran Lian and colleagues analysed 313 patients with locally advanced non-small-cell lung cancer. One centre supplied 142 training and 61 internal-validation cases; a second supplied 110 external cases. Voxel-wise PET and CT thresholds formed four intersected habitats, six classifiers were compared, and the decision threshold was fixed from training data. Tissue testing defined EGFR mutation status.

The SVM habitat model reported AUCs of 0.911, 0.898 and 0.884 across training, internal and external cohorts; a combined model reached external AUC 0.904. External sensitivity, specificity, accuracy and NPV were 0.750, 0.739, 0.745 and 0.680. The independent-centre result supports prospective study, but the NPV is insufficient to rule out mutation and the retrospective model cannot replace tissue or plasma molecular testing. PubMed record.

Read the source · PubMed record

A cardiac-CT Transformer predicts atherectomy use, not clinical necessity — 5 November 2026 catch-up

Rissei Hino and colleagues trained a ConvNeXt-plus-Transformer multiple-instance model on 498 calcified lesions from 419 patients. Twelve institutions supplied four-fold development data; two independent institutions supplied 97 external lesions. A training-derived threshold was applied unchanged.

Read findings, evidence and limitations

Rissei Hino and colleagues trained a ConvNeXt-plus-Transformer multiple-instance model on 498 calcified lesions from 419 patients. Twelve institutions supplied four-fold development data; two independent institutions supplied 97 external lesions. A training-derived threshold was applied unchanged. External AUC was 0.788 from CCTA alone and 0.805 after adding seven clinical variables.

External accuracy was 0.742, compared with 0.619 for general cardiologists (p=0.029) and 0.670 for PCI experts (p=0.230). The endpoint was operators’ historical atherectomy use, not procedural appropriateness or patient outcome. Development folds were lesion-level; because some patients contributed multiple lesions, the surfaced methods do not rule out same-patient leakage across folds. European Heart Journal – Digital Health paper.

Read the source · European Heart Journal – Digital Health paper

CT-to-BMD ensemble complexity does not significantly beat the best single model — 5 November 2026 catch-up

Satoru Tanioka and colleagues compared simple HU regression, radiomics, CNN and ensemble estimation of DXA bone mineral density using four hospitals. T12 analysis included 465 patients and L1 included 448; two institutions were reserved for external testing. At T12, the ensemble’s MAE/RMSE/R² were 0.128/0.154/0.620 versus 0.122/0.157/0.603 for the CNN.

Read findings, evidence and limitations

Satoru Tanioka and colleagues compared simple HU regression, radiomics, CNN and ensemble estimation of DXA bone mineral density using four hospitals. T12 analysis included 465 patients and L1 included 448; two institutions were reserved for external testing. At T12, the ensemble’s MAE/RMSE/R² were 0.128/0.154/0.620 versus 0.122/0.157/0.603 for the CNN. At L1, the ensemble achieved 0.116/0.145/0.633 versus 0.124/0.155/0.582 for radiomics.

Absolute-error differences from the best single model were not significant. The study’s contribution is the controlled comparison and institution-level external test, not an ensemble-win claim. The abstract does not expose exact site counts or scanner-protocol transport details, and clinical osteoporosis thresholds or impact were not evaluated. PubMed record.

Read the source · PubMed record

A CT xerostomia review finds wide AUCs but only moderate methodological quality — 9 November 2026

Nicola Jones-Anderson and colleagues reviewed 22 studies with cohorts from 19 to 1,208 patients; 14 used CT. Endpoints varied across clinician grading, patient reports and salivary output. Reported CT AUCs ranged from 0.64 to 0.93, and delta-radiomics studies reported 0.86–0.93, but mean Radiomics Quality Score was only 14/36.

Read findings, evidence and limitations

Nicola Jones-Anderson and colleagues reviewed 22 studies with cohorts from 19 to 1,208 patients; 14 used CT. Endpoints varied across clinician grading, patient reports and salivary output. Reported CT AUCs ranged from 0.64 to 0.93, and delta-radiomics studies reported 0.86–0.93, but mean Radiomics Quality Score was only 14/36.

The review argues that limited external validation, absent prospective work, weak open-science practice and missing cost-effectiveness analysis prevent routine clinical readiness. It is a structured narrative review rather than a meta-analysis, so heterogeneous endpoints and designs preclude a pooled performance estimate. Cambridge University Press review.

Read the source · Cambridge University Press review

A small CT preprint localises cochlear landmarks with at most 16 training volumes — posted 8 November 2026

Yifan Wang and colleagues describe MEDICO-YOLO for six cochlear landmarks total—apex, basal point and round-window centre in each cochlea—in 0.3-mm preoperative CT. Training experiments used 4, 8, 12 or 16 volumes and testing used 16. The abstract reports mean error of 1.30 mm with eight training volumes and 0.71 mm with 16, plus 97.92% success within 3 mm and 25.43-second whole-volume latency on an Apple M1.

Read findings, evidence and limitations

Yifan Wang and colleagues describe MEDICO-YOLO for six cochlear landmarks total—apex, basal point and round-window centre in each cochlea—in 0.3-mm preoperative CT. Training experiments used 4, 8, 12 or 16 volumes and testing used 16. The abstract reports mean error of 1.30 mm with eight training volumes and 0.71 mm with 16, plus 97.92% success within 3 mm and 25.43-second whole-volume latency on an Apple M1.

This is a non-peer-reviewed medRxiv preprint with extremely small samples, no external centre or device validation, and uncertain confidence around the reported estimates. It is best treated as a feasibility signal, not a clinical localisation result. medRxiv DOI.

Read the source · medRxiv DOI

Synthesis and practical implications

Across the studies, validation labels are less informative than data flow. An “external” cohort cannot support independent validation if it helped select one of 97 pipelines. A multicentre pool does not demonstrate transport when centres are mixed across a random split. A lesion-level cross-validation scheme may still leak patient-specific information when patients contribute multiple lesions. Centre-held-out tests and training-fixed thresholds strengthen evidence only when feature, algorithm and threshold choices are all locked before evaluation.

Three reporting upgrades would make these studies easier to use. First, publish a complete selection graph showing where imputation, harmonisation, feature selection, model choice and threshold choice were fitted. Second, report simple baselines, calibration and clinically interpretable operating points alongside AUC or C-index. Third, name the endpoint precisely: historical device use is not appropriateness, molecular-probability estimation is not genotyping, and retrospective survival discrimination is not improved survival.

News from major medical data and imaging developers

TCIA advances LDCT-and-Projection-data to Version 8 without documenting a substantive delta — 9 November 2026

The Cancer Imaging Archive now lists Version 8 of its matched routine-dose and simulated lower-dose CT collection with raw projections, acquisition geometry and reconstructed images. The catalogue covers 299 cases: 99 head, 100 chest and 100 abdomen/liver.

Read findings, evidence and limitations

The Cancer Imaging Archive now lists Version 8 of its matched routine-dose and simulated lower-dose CT collection with raw projections, acquisition geometry and reconstructed images. The catalogue covers 299 cases: 99 head, 100 chest and 100 abdomen/liver. Current tables list 99 chest subjects with 2,267,266 images, 100 liver subjects with 5,759,639 images, 99 head subjects with 4,968,595 images and one phantom with 18,032 images, totalling about 1.29 TB.

Chest, liver and phantom data are CC BY 4.0; head data require NIH controlled access because facial reconstruction may be possible. The DICOM-CT-PD dictionary and reader are CC BY 3.0. The official Version 8 changelog is empty, so this edition does not claim new scans, a reconstruction benchmark or a specific v7-to-v8 data delta. No files were retrieved. TCIA collection.

Read the source · TCIA collection

MedMLX publishes lesiondiffusion-mlx 0.2.8 for 3D CT lesion synthesis — 9 November 2026 catch-up

MedMLX’s Apple-Silicon package accepts a CT NIfTI volume in Hounsfield units plus an aligned organ mask and outputs a synthetic CT and lesion mask. Controls cover organ, lesion type, bounding box, text phenotype, diffusion steps and seed; regional output modes can blend a box or lesion-local neighbourhood while retaining the raw synthetic result.

Read findings, evidence and limitations

MedMLX’s Apple-Silicon package accepts a CT NIfTI volume in Hounsfield units plus an aligned organ mask and outputs a synthetic CT and lesion mask. Controls cover organ, lesion type, bounding box, text phenotype, diffusion steps and seed; regional output modes can blend a box or lesion-local neighbourhood while retaining the raw synthetic result. The current card reports peak memory of 5.19 GB in conditioned mode and 3.46 GB in source mode for one 160×160×128 AMOS crop at 200 steps.

Those are single-case engineering measurements, not clinical or detection results. The card warns that lesions may extend beyond requested bounds and non-lesion attenuation can shift. Version 0.2.8 has no located version-specific changelog, so the incremental change from the previously covered 0.2.7 release is unresolved. The beta package is Apache-2.0 with MIT/BSD components; separately downloaded weights keep their own terms. PyPI release.

Read the source · PyPI release

eehrxf 0.3.0 maps EHDS-oriented openEHR and FHIR structures with provenance hooks — 9 November 2026

Cadasto/FerroHEALTH’s Rust crate reads Xt-EHR logical information models for patient summaries, prescriptions, dispensations, imaging, laboratory and discharge data; maps between openEHR canonical JSON and FHIR R4; and can retain incoming originals in FEEDER_AUDIT.

Read findings, evidence and limitations

Cadasto/FerroHEALTH’s Rust crate reads Xt-EHR logical information models for patient summaries, prescriptions, dispensations, imaging, laboratory and discharge data; maps between openEHR canonical JSON and FHIR R4; and can retain incoming originals in FEEDER_AUDIT. Its documentation describes validation of bundle/profile constraints, cardinalities, slices and fixed values, plus terminology checks for SNOMED CT, LOINC, ICD-10 and FHIR services.

docs.rs reports 233/233 public items documented, but this is documentation coverage rather than interoperability validation; the owner reports no hospital cohort, interoperability event, conformance-suite result or error-rate study. The rapid same-day version train has no human-readable 0.3.0 changelog. BSL 1.1 permits non-production and non-commercial production use; other production use needs a commercial licence, with an Apache-2.0 change after four years. eehrxf documentation.

Read the source · eehrxf documentation

FerroHEALTH’s 0.10.0 audit stack links DICOM/IHE transport to EHDS logging categories — 9 November 2026

The coordinated ihe-atna and ehds-logging crates implement DICOM PS3.15 audit messages over RFC 5424/5425 syslog with TLS, bounded store-and-forward, retry, quarantine and redaction; FHIR R4 BALP AuditEvent transport; and mappings to EHDS access categories. The logging documentation references six priority categories from the HL7 Europe health-data-api ballot.

Read findings, evidence and limitations

The coordinated ihe-atna and ehds-logging crates implement DICOM PS3.15 audit messages over RFC 5424/5425 syslog with TLS, bounded store-and-forward, retry, quarantine and redaction; FHIR R4 BALP AuditEvent transport; and mappings to EHDS access categories. The logging documentation references six priority categories from the HL7 Europe health-data-api ballot.

This is implementation documentation, not proof of production privacy, IHE conformance or EHDS compliance. No independent conformance result, penetration test, event-volume benchmark or hospital deployment was reported, and deployers still control mappings, certificates, retention and jurisdictional requirements. Both crates use the same BSL 1.1 production restrictions and four-year Apache conversion. ihe-atna · ehds-logging.

Read the source · ihe-atna

IsiX DICOM Viewer 6.0.0-beta4 adds cross-study pan synchronisation and expands migration and diagnostic handling — 10 November 2026

Thales Santos’s macOS pre-release adds locked-study pan propagation, expands support and plug-in migration for Horos-era installations, improves DICOM-print log handling, and reports idle DICOM associations more clearly. The release continues the beta line’s diagnostic and workflow work rather than presenting a clinical algorithm.

Read findings, evidence and limitations

Thales Santos’s macOS pre-release adds locked-study pan propagation, expands support and plug-in migration for Horos-era installations, improves DICOM-print log handling, and reports idle DICOM associations more clearly. The release continues the beta line’s diagnostic and workflow work rather than presenting a clinical algorithm.

The owner reports focused tests, but there is no clinical-accuracy, inter-reader, external-conformance or performance study. The software is a beta, requires macOS 15+, and its source is LGPL-3.0 while branding is separately reserved. GitHub beta4 release.

Read the source · GitHub beta4 release

CodePawl converts seven CT-derived bodies into compact GLB anatomy assets — 4–7 November 2026 catch-up

CodePawl’s CC BY 4.0 dataset contains 27 assets: seven real CT-derived bodies and 20 organ or system models, with up to 115 named structures per body and several levels of detail. The pipeline converts TotalSegmentator v2.0.1 masks into smoothed and decimated meshes. The card reports 2,515,782 final triangles from 20,238,966 raw triangles and a 20.07 MB body/organ package.

Read findings, evidence and limitations

CodePawl’s CC BY 4.0 dataset contains 27 assets: seven real CT-derived bodies and 20 organ or system models, with up to 115 named structures per body and several levels of detail. The pipeline converts TotalSegmentator v2.0.1 masks into smoothed and decimated meshes. The card reports 2,515,782 final triangles from 20,238,966 raw triangles and a 20.07 MB body/organ package.

The seven cases span ages 31–94 and include two men and five women. Import and orientation checks were owner-run in three.js, Blender and Unreal; no geometric error, segmentation Dice or clinical review was reported. Small structures are simplified, some extremities are absent, and source-segmentation errors propagate. The resource is for visualisation and education, not diagnosis. Hugging Face dataset card.

Read the source · Hugging Face dataset card

Coverage

The strict interval was after 9 November 2026 06:08:15 UTC through 10 November 2026 06:13:56 UTC, with a rolling seven-day catch-up from 3 November 2026 06:13:56 UTC. The Medical Data ledger contained 110 previously covered story URLs or identifiers from 5–9 November; none of the 18 reported research and release records matched it. The research stream retained 11 peer-reviewed records plus one small CT preprint, and the official-release stream retained six records. Lower-value, out-of-scope, older-by-true-date, previously covered and insufficiently documented records were excluded.

PubMed, medRxiv, arXiv, MICCAI/MIDL/MLHC discovery, publisher families and official developer/institution sources were checked. No genuinely date-new MIDL, MLHC or MICCAI proceeding and no clearly eligible strict-window arXiv paper were found. Web of Science and Scopus were unavailable, so neither was queried. No 30/90-day publisher backfill was used because current and seven-day journal coverage was sufficient. Direct Elsevier, IEEE and RSNA families were preserved in discovery even though no new eligible article was retained from some families.

Several publisher and catalogue pages expose only calendar dates, so those records remain date-level candidates. Registry and release APIs that expose exact UTC timestamps—including PyPI, crates.io and GitHub—were adjudicated directly against the cutoffs. Access failure or an empty changelog was not treated as evidence of no activity; unsupported version deltas were omitted. No patient-level records, CT/DICOM files, masks, model weights, meshes or release binaries were retrieved.

Verification: two independent source checks passed; experiments were not independently reproduced.

Latest Medical data briefing