Daily briefings
ATLAS

Research. Knowledge. Opportunity.
A clearer view of what comes next.

Medical data structure can travel when outcome associations do not

Archived edition. Findings, availability and deadlines reflect this report’s date; consult current original sources before acting.

Daily briefing · 13 November 2026

Today’s evidence separates reproducible data structure from reliable clinical inference. In neurocritical-care records, a locked chloride-trajectory model reproduced its four shapes across MIMIC-IV and eICU, yet the trajectories’ mortality associations did not transport. A cervical spinal-cord-injury model showed the same broader lesson from another angle: its internal AUC of 0.956 fell to 0.738 at an independent hospital. These are useful results because they make the transport failure visible rather than hiding it behind a strong development score.

The CT stream is more conditional. A small CT–clinical neuroblastoma model reported promising progression-free-survival discrimination, but its 105-patient, single-cohort evaluation and unclear split description limit the claim. A delayed post-CTA marker for haematoma expansion reached only moderate cross-validated discrimination. The lower-limb resource uses a subject-level 19-person/one-person train/test split, but its test set contains only one person and two limbs. The common issue is independence: patients, sites and acquisition domains matter more than the number of slices or derived features.

Release activity reinforces that point at the infrastructure layer. PhysioNet removed documented report overlap from a CPT-labelling benchmark; ITK corrected a DICOM orientation failure that could silently reverse the physical z-axis; and FHIR, DICOM-viewer and device-data releases tightened interoperability. These changes improve the conditions for trustworthy analysis, but none independently demonstrates clinical benefit, privacy or regulatory readiness.

Edition links

Medical Data desk · 13 November 2026 briefing · Medical Data archive

Peer-reviewed research

Structured clinical data — chloride phenotypes transport, but their mortality associations do not

Published 11 November 2026; peer-reviewed catch-up. A Frontiers in Neurology study used an outcome-blind, four-class quadratic group-based trajectory model for early serum chloride, locked its MIMIC-IV parameters, and applied them unchanged to eICU. The 72-hour landmark cohorts contained 1,817 MIMIC-IV patients, including 382 deaths, and 1,154 eICU patients, including 197 deaths, with traumatic brain injury, intracerebral haemorrhage or nontraumatic subarachnoid haemorrhage. Fifty database-specific multiply imputed datasets, posterior-probability class draws and a competing-risk model addressed missingness and class uncertainty. No clear acute-kidney-injury association emerged.

Read findings, evidence and limitations

Published 11 November 2026; peer-reviewed catch-up. A Frontiers in Neurology study used an outcome-blind, four-class quadratic group-based trajectory model for early serum chloride, locked its MIMIC-IV parameters, and applied them unchanged to eICU. The 72-hour landmark cohorts contained 1,817 MIMIC-IV patients, including 382 deaths, and 1,154 eICU patients, including 197 deaths, with traumatic brain injury, intracerebral haemorrhage or nontraumatic subarachnoid haemorrhage. Fifty database-specific multiply imputed datasets, posterior-probability class draws and a competing-risk model addressed missingness and class uncertainty.

Structural transport was strong: class-by-window RMSE was 0.93 mmol/L and kappa was 0.900. Prognostic transport was not. In MIMIC-IV, the global mortality association was significant (p<0.001), and adjusted subdistribution hazard ratios versus the mid-stable class were 1.87 for low-stable, 1.49 for high-rising and 2.96 for very-high/plateau trajectories. In eICU, the corresponding values were 0.77, 0.77 and 1.21, with global p=0.166. No clear acute-kidney-injury association emerged. The outcome-blind phenotype selection and fixed external parameters reduce leakage, but the landmark excludes early deaths and conditions on 72-hour survival and measurement. This is evidence that phenotype structure and outcome association require separate transport tests, not that chloride is a treatment target. Primary source

Read the source · Primary source

Structured clinical data — external testing cuts cervical-injury mortality discrimination

Published 12 November 2026; peer-reviewed, with exact release time unavailable. A cervical spinal-cord-injury study developed 28-day mortality models in 232 MIMIC-IV patients and tested the selected support-vector machine at the Second Hospital of Shanxi Medical University in 210 patients. Within development data, the authors used a stratified 70:30 split, repeated 10-fold cross-validation, training-fold-only SMOTE, and the intersection of recursive feature elimination and Boruta. The final 11 variables included APACHE II, APS III, temperature, age, glucose, bicarbonate, base excess, norepinephrine, arterial pH, heart rate and lactate. The internal test AUC was 0.956 (95% CI 0.895–1.000), but external AUC was 0.738 (0.664–0.812).

Read findings, evidence and limitations

Published 12 November 2026; peer-reviewed, with exact release time unavailable. A cervical spinal-cord-injury study developed 28-day mortality models in 232 MIMIC-IV patients and tested the selected support-vector machine at the Second Hospital of Shanxi Medical University in 210 patients. Within development data, the authors used a stratified 70:30 split, repeated 10-fold cross-validation, training-fold-only SMOTE, and the intersection of recursive feature elimination and Boruta. The final 11 variables included APACHE II, APS III, temperature, age, glucose, bicarbonate, base excess, norepinephrine, arterial pH, heart rate and lactate.

The internal test AUC was 0.956 (95% CI 0.895–1.000), but external AUC was 0.738 (0.664–0.812). Feature selection and SMOTE were confined to training data; fold-specific imputation could not be verified, so preprocessing-related optimism remains possible. Event counts were not exposed in the accessible abstract, calibration was a secondary saved-probability analysis, and the study did not test prospective clinical impact. The external result, rather than the development headline, is the defensible estimate of transport. Primary source

Read the source · Primary source

Structured clinical data — sepsis “time zero” changes with the organ-dysfunction trigger

Published 12 November 2026; peer-reviewed accepted manuscript, with exact release time unavailable. An EHR cohort study examined 1,849,729 suspected-infection encounters across 145 US hospitals from 2018–2023. The primary analysis included 624,416 encounters with at least one SEP-1 organ-dysfunction trigger and antibiotics within six hours, using inverse-probability weighting for baseline and time-varying confounding. This was association modelling rather than a train/test prediction exercise. For antibiotics at one to three hours versus zero to one hour, adjusted mortality risk ratios were 1.07 (95% CI 1.03–1.10) after hypotension and 1.10 (1.05–1.15) after lactate of at least 4 mmol/L; no corresponding association appeared for other dysfunctions alone or in combination.

Read findings, evidence and limitations

Published 12 November 2026; peer-reviewed accepted manuscript, with exact release time unavailable. An EHR cohort study examined 1,849,729 suspected-infection encounters across 145 US hospitals from 2018–2023. The primary analysis included 624,416 encounters with at least one SEP-1 organ-dysfunction trigger and antibiotics within six hours, using inverse-probability weighting for baseline and time-varying confounding. This was association modelling rather than a train/test prediction exercise.

For antibiotics at one to three hours versus zero to one hour, adjusted mortality risk ratios were 1.07 (95% CI 1.03–1.10) after hypotension and 1.10 (1.05–1.15) after lactate of at least 4 mmol/L; no corresponding association appeared for other dysfunctions alone or in combination. Without hypotension or high lactate, treatment at three to six hours versus zero to three hours was associated with mortality only for acute respiratory failure, aRR 1.11 (1.05–1.18). The study shows that an operational label can change the measured timing signal. Residual confounding, treatment selection and timestamp error prevent a causal or individualized-treatment interpretation, and the result does not support delaying antibiotics. Primary source

Read the source · Primary source

Multimodal CT–clinical data — a small neuroblastoma model remains internally evaluated

Published 12 November 2026; peer-reviewed accepted manuscript, with exact release time unavailable. A retrospective study combined clinical variables, CT imaging characteristics and multiphase radiomics to estimate progression-free survival in 105 children with pathologically confirmed high-risk neuroblastoma. Support-vector-machine variants used radiomics alone and combinations of clinical, imaging and radiomic inputs; a Cox-based nomogram retained MYCN amplification and image-defined risk-factor presence. However, the publisher abstract describes an 80:20 train/test split while also reporting training, validation and test results, so the exact allocation and feature-selection nesting remain unresolved.

Read findings, evidence and limitations

Published 12 November 2026; peer-reviewed accepted manuscript, with exact release time unavailable. A retrospective study combined clinical variables, CT imaging characteristics and multiphase radiomics to estimate progression-free survival in 105 children with pathologically confirmed high-risk neuroblastoma. Support-vector-machine variants used radiomics alone and combinations of clinical, imaging and radiomic inputs; a Cox-based nomogram retained MYCN amplification and image-defined risk-factor presence.

The full combined model reported AUCs of 0.855 in training, 0.796 in validation and 0.856 in testing; the nomogram’s bootstrap C-index was 0.806 (p=0.028). However, the publisher abstract describes an 80:20 train/test split while also reporting training, validation and test results, so the exact allocation and feature-selection nesting remain unresolved. There was no independent site or prospective validation, and the cohort is small for a multimodal pipeline. The work provides a hypothesis for CT–clinical integration, not a validated prognostic tool. Primary source

Read the source · Primary source

CT data — dense lower-limb labels come from 20 healthy people

Published 12 November 2026; peer-reviewed Scientific Data descriptor, with exact release time unavailable. A new lower-limb CT segmentation resource contains high-resolution scans from 20 healthy participants—10 women and 10 men—represented as 40 individual lower-limb cases, two limbs per participant. Experts labelled 44 structures per limb, comprising 31 skeletal and 13 muscular structures, producing 92,603 axial, coronal and sagittal 2D image–mask pairs. The paper states that both limbs and all slices from each participant remain in one partition.

Read findings, evidence and limitations

Published 12 November 2026; peer-reviewed Scientific Data descriptor, with exact release time unavailable. A new lower-limb CT segmentation resource contains high-resolution scans from 20 healthy participants—10 women and 10 men—represented as 40 individual lower-limb cases, two limbs per participant. Experts labelled 44 structures per limb, comprising 31 skeletal and 13 muscular structures, producing 92,603 axial, coronal and sagittal 2D image–mask pairs.

Five architectures were benchmarked using a subject-level split of 19 participants (38 limbs) for training and one participant (two limbs) for testing; UPerNet performed best, with IoU 0.5943 and DSC 0.7234. The paper states that both limbs and all slices from each participant remain in one partition. However, a one-person test set cannot provide a stable generalisation estimate, and the small healthy cohort cannot establish performance under pathology, scanner or site shift. The contribution is annotation density, not independent sample size: 92,603 image pairs still come from 20 people. Primary source

Read the source · Primary source

CT data — post-CTA cluster spread is associated with haematoma expansion

Published 12 November 2026; peer-reviewed, with exact release time unavailable. A single-centre retrospective study transformed delayed post-CTA contrast-pooling geometry into a three-dimensional cluster-spread marker for haematoma expansion after spontaneous intracerebral haemorrhage. The parent cohort contained 403 patients; the primary model was restricted to 128 patients positive at a 98-HU threshold previously derived at the same institution. Baseline haemorrhage masks were co-registered to delayed post-CTA scans, 13 spatial metrics were prespecified, and expansion was defined as more than 6 mL or 33% on follow-up CT within 36 hours. The result is an association with moderate internal discrimination, not an externally validated prediction tool; the single site, wide confidence interval, threshold provenance and conditioning on positivity all constrain generalisation.

Read findings, evidence and limitations

Published 12 November 2026; peer-reviewed, with exact release time unavailable. A single-centre retrospective study transformed delayed post-CTA contrast-pooling geometry into a three-dimensional cluster-spread marker for haematoma expansion after spontaneous intracerebral haemorrhage. The parent cohort contained 403 patients; the primary model was restricted to 128 patients positive at a 98-HU threshold previously derived at the same institution. Baseline haemorrhage masks were co-registered to delayed post-CTA scans, 13 spatial metrics were prespecified, and expansion was defined as more than 6 mL or 33% on follow-up CT within 36 hours.

Expansion occurred in 52 of 128 positive patients and 12 of 275 negative patients. Marker positivity had an odds ratio of 15.0 (95% CI 7.6–29.5); within positive patients, 3D cluster spread had adjusted OR 7.27 (1.79–29.45), p=0.005. Five-fold cross-validated AUC was 0.69. The result is an association with moderate internal discrimination, not an externally validated prediction tool; the single site, wide confidence interval, threshold provenance and conditioning on positivity all constrain generalisation. Primary source

Read the source · Primary source

Structured clinical data — federated SHAP ranks are consistent, not necessarily faithful

Published 12 November 2026; peer-reviewed, with exact release time unavailable. A Scientific Reports benchmark compared global SHAP feature-importance ranks from centralized and federated ICU-mortality models across MIMIC-III, MIMIC-IV and eICU. Nine architecture-matched comparisons spanning LightGBM/XGBoost, cyclic boosting and TabPFN-teacher/XGBoost-student variants produced Spearman rank correlations from 0.6463 to 0.8374. Federated distilled-student AUROCs were 0.8294, 0.8402 and 0.8515 across the three datasets. It does not establish explanation faithfulness, bedside usefulness, privacy or cross-hospital transport.

Read findings, evidence and limitations

Published 12 November 2026; peer-reviewed, with exact release time unavailable. A Scientific Reports benchmark compared global SHAP feature-importance ranks from centralized and federated ICU-mortality models across MIMIC-III, MIMIC-IV and eICU. Nine architecture-matched comparisons spanning LightGBM/XGBoost, cyclic boosting and TabPFN-teacher/XGBoost-student variants produced Spearman rank correlations from 0.6463 to 0.8374. Federated distilled-student AUROCs were 0.8294, 0.8402 and 0.8515 across the three datasets.

This supports moderate-to-high agreement in global feature ordering under the studied simulation. It does not establish explanation faithfulness, bedside usefulness, privacy or cross-hospital transport. The full paper reports 33,266 MIMIC-III, 54,211 MIMIC-IV and 11,897 eICU patients, with patient-grouped 80/10/10 training-pool/validation/test partitions and ten-bin calibration curves. MIMIC client sites were simulated through random patient partitioning, whereas eICU clients mapped to four actual hospitals. No differential privacy, secure aggregation, encryption-based protection or membership-inference evaluation was implemented. Primary source

Read the source · Primary source

Other new and catch-up findings

CT-report data — model agreement varies by incidental finding

First posted 10 November 2026; medRxiv preprint, not peer reviewed. A benchmark compared GPT-5, GPT-4-Turbo, Llama-3.1-8B-Instruct, MedGemma-4B-IT and keyword search for nine incidental-finding labels in 300 Dutch academic-hospital lung-screening CT reports, using one radiologist as the reference. GPT-5 achieved kappa from 0.71 to 0.97 for seven labels; the best reported agreement for interstitial lung abnormalities was 0.48 and for mediastinal mass 0.42. Non-chain-of-thought prompts led most categories, and no model/prompt combination dominated every label. This is report labelling, not CT-image interpretation or cancer-outcome prediction.

Read findings, evidence and limitations

First posted 10 November 2026; medRxiv preprint, not peer reviewed. A benchmark compared GPT-5, GPT-4-Turbo, Llama-3.1-8B-Instruct, MedGemma-4B-IT and keyword search for nine incidental-finding labels in 300 Dutch academic-hospital lung-screening CT reports, using one radiologist as the reference. GPT-5 achieved kappa from 0.71 to 0.97 for seven labels; the best reported agreement for interstitial lung abnormalities was 0.48 and for mediastinal mass 0.42. Non-chain-of-thought prompts led most categories, and no model/prompt combination dominated every label.

This is report labelling, not CT-image interpretation or cancer-outcome prediction. The single centre, 300 reports, one reference reader, unstated patient-duplication controls and closed-model version drift limit generalisation and reproducibility. Primary source

Read the source · Primary source

Synthesis and practical implications

  • Transport the relationship, not only the representation. The chloride study shows that stable classes can coexist with unstable outcome associations; the spinal-injury study shows the same problem as an internal-to-external AUC loss.
  • Keep data independence visible. Twenty participants cannot become 92,603 independent CT cases, and a 105-patient multimodal pipeline remains small even when it generates many radiomic features.
  • Operational definitions are model inputs. Sepsis time zero, CT positivity thresholds and label construction can change the target and therefore the claim.
  • Report calibration, decision utility and simple baselines alongside discrimination. Internal AUCs, cross-validation and bootstrap validation do not substitute for an untouched site or prospective impact assessment.
  • Separate privacy, correctness and clinical utility. Removing benchmark overlap or fixing geometry improves data integrity, but neither proves privacy or patient benefit.

News from major medical data and imaging developers

PhysioNet — MIMIC-IV-Ext-CPT removes documented train/test report overlap

Published 12 November 2026; official release, exact time unavailable. Version 1.0.1 removes 30 annotated test records—29 exact matches and one normalized-only match—whose report text also occurred in training. The training and auxiliary files are unchanged. The release contains 30,938 curated training records, 7,705 annotated test records and 412,297 weakly labelled admission-level auxiliary records, for 450,940 records and 322 test labels. Maintainers report zero remaining exact or normalized report-text overlap after Unicode, whitespace and case normalization. This is a concrete contamination repair, not a new model result.

Read findings, evidence and limitations

Published 12 November 2026; official release, exact time unavailable. Version 1.0.1 removes 30 annotated test records—29 exact matches and one normalized-only match—whose report text also occurred in training. The training and auxiliary files are unchanged. The release contains 30,938 curated training records, 7,705 annotated test records and 412,297 weakly labelled admission-level auxiliary records, for 450,940 records and 322 test labels. Maintainers report zero remaining exact or normalized report-text overlap after Unicode, whitespace and case normalization.

This is a concrete contamination repair, not a new model result. Labels come from structured fields, auxiliary labels are admission-level, patient/admission split independence is not established on the release page, and semantic near-duplicates may remain. Access requires PhysioNet credentialing, training and a data-use agreement under the PhysioNet Credentialed Health Data License 1.5.0. Official release

Read the source · Official release

IsiX DICOM Viewer — a major workflow release receives two strict-window stabilization patches

Version 6.0.0 released 12 November 2026 at 04:39 UTC; version 6.0.1 at 14:08 UTC; version 6.0.2 on 13 November at 04:37 UTC. The substantive v6.0.0 release introduces a modular Swift architecture, IsiXPluginKit v1, Horos/OsiriX plug-in compatibility, Modality Worklist, study migration and state handling, image/ROI operations, T1 mapping and synthetic-DWI export. The v6.0.1 patch updates DICOM-Swift and fixes series scrolling, floating panels, PDF background, source stamping and archive reproducibility. The latest in-window v6.0.2 patch addresses database-file identity, plug-in discovery and recovery, report generation, DICOM export and printing, temporary viewer settings, and image/PDF drag-and-drop, with maintainer regression tests. These are software-workflow changes with no diagnostic-performance evaluation.

Read findings, evidence and limitations

Version 6.0.0 released 12 November 2026 at 04:39 UTC; version 6.0.1 at 14:08 UTC; version 6.0.2 on 13 November at 04:37 UTC. The substantive v6.0.0 release introduces a modular Swift architecture, IsiXPluginKit v1, Horos/OsiriX plug-in compatibility, Modality Worklist, study migration and state handling, image/ROI operations, T1 mapping and synthetic-DWI export. The v6.0.1 patch updates DICOM-Swift and fixes series scrolling, floating panels, PDF background, source stamping and archive reproducibility. The latest in-window v6.0.2 patch addresses database-file identity, plug-in discovery and recovery, report generation, DICOM export and printing, temporary viewer settings, and image/PDF drag-and-drop, with maintainer regression tests.

These are software-workflow changes with no diagnostic-performance evaluation. IsiX is an independently maintained, unofficial Horos fork; license and branding notices are mixed and need bundle-level review, and the Intel package was reportedly not tested on Intel hardware. Official releases

Read the source · Official releases

ITK — version 5.4.8 corrects affected DICOM physical orientation

Released 11 November 2026; official package catch-up. ITK 5.4.8 fixes ImageSeriesReader choosing an incorrect direction matrix when DICOM SpacingBetweenSlices sign conflicts with slice ordering, a condition that could silently reverse the physical z-axis in affected CT/DICOM series. Maintainer regression coverage spans axis-aligned and oblique images, axial/sagittal/coronal cases, reversed ordering, orthonormality and physical-point invariance. This is software-correctness evidence, not clinical validation.

Read findings, evidence and limitations

Released 11 November 2026; official package catch-up. ITK 5.4.8 fixes ImageSeriesReader choosing an incorrect direction matrix when DICOM SpacingBetweenSlices sign conflicts with slice ordering, a condition that could silently reverse the physical z-axis in affected CT/DICOM series. Maintainer regression coverage spans axis-aligned and oblique images, axial/sagittal/coronal cases, reversed ordering, orthonormality and physical-point invariance.

This is software-correctness evidence, not clinical validation. The Apache-2.0 package appeared on official PyPI while ITK’s GitHub Releases index still lagged at 5.4.7. SimpleITK 2.5.7 confirms that it is built on ITK 5.4.8; the negative-spacing and direction-cosine fix is documented in the SimpleITK issue and tagged ITK regression test. Package record · SimpleITK issue · ITK regression test

Read the source · ITK regression test

LinuxForHealth — FHIR Server 5.1.0 repairs search and validation behaviour

Released 11 November 2026 at 22:38 UTC; official catch-up. LinuxForHealth FHIR Server 5.1.0 repairs a long-searchable-string regression from 5.0.0, adds Da Vinci PDex US Drug Formulary STU2 support, implements FHIRPath is/as inheritance and stronger string-pattern validation, warns when search pages shift, truncates long string parameters before persistence, and reduces the default initial heap size. It supports FHIR R4 4.0.1 and R4B 4.3.0. The Apache-2.0 release provides Docker, installer, CLI and Maven artifacts, but no independent interoperability benchmark.

Read findings, evidence and limitations

Released 11 November 2026 at 22:38 UTC; official catch-up. LinuxForHealth FHIR Server 5.1.0 repairs a long-searchable-string regression from 5.0.0, adds Da Vinci PDex US Drug Formulary STU2 support, implements FHIRPath is/as inheritance and stronger string-pattern validation, warns when search pages shift, truncates long string parameters before persistence, and reduces the default initial heap size. It supports FHIR R4 4.0.1 and R4B 4.3.0.

The Apache-2.0 release provides Docker, installer, CLI and Maven artifacts, but no independent interoperability benchmark. Tenants must be present in configuration at startup, and the maintainer warns that Binary.securityContext does not affect access control for fhir-smart. Official release

Read the source · Official release

Aidbox — release 2610 adds encryption, patient matching and migration-heavy interoperability changes

Announced 11 November 2026; official vendor catch-up. Health Samurai’s Aidbox 2610 adds selected-field JWE encryption at rest with external secrets, ValueSet and ConceptMap dependencies for SQLQuery/SQLView, offloaded binary blobs in Bulk Data Export, application AuditEvents and streaming HTTP-RPC. MDMbox adds versioned probabilistic or deterministic patient-matching models over FHIR views; Formbox propagates confidentiality labels; Interbox 2.x adds step-based TypeScript pipelines and connector/retry changes. These are vendor claims without independent performance or matching-accuracy results.

Read findings, evidence and limitations

Announced 11 November 2026; official vendor catch-up. Health Samurai’s Aidbox 2610 adds selected-field JWE encryption at rest with external secrets, ValueSet and ConceptMap dependencies for SQLQuery/SQLView, offloaded binary blobs in Bulk Data Export, application AuditEvents and streaming HTTP-RPC. MDMbox adds versioned probabilistic or deterministic patient-matching models over FHIR views; Formbox propagates confidentiality labels; Interbox 2.x adds step-based TypeScript pipelines and connector/retry changes.

These are vendor claims without independent performance or matching-accuracy results. Custom SMART compartments need {def}, standalone Formbox is removed, and Interbox 1.x migration requires backup, downtime and load planning. The free development licence is not for PHI or production; production or PHI use requires a commercial licence. Vendor announcement

Read the source · Vendor announcement

HL7 — Personal Health Device Implementation Guide 2.0.1 publishes trial-use errata

Announced 10 November and built around 13:55 UTC that day; official catch-up. The HL7 International Devices Working Group’s STU 2 errata update maps communicating personal-health-device measurements and device information into FHIR R4 for EMR, decision-support, archive and research use. The explicit 2.0.1 change list restores the PhdCoincidentTimeStampObservation introduction and notes, adds object identifiers, documents permissions for IEEE 11073-10101 and Continua code systems, and fixes headings and duplicate titles. The maturity-level-2 trial-use guide transports and maps observations; it does not interpret them or solve provenance, privacy, security or consent.

Read findings, evidence and limitations

Announced 10 November and built around 13:55 UTC that day; official catch-up. The HL7 International Devices Working Group’s STU 2 errata update maps communicating personal-health-device measurements and device information into FHIR R4 for EMR, decision-support, archive and research use. The explicit 2.0.1 change list restores the PhdCoincidentTimeStampObservation introduction and notes, adds object identifiers, documents permissions for IEEE 11073-10101 and Continua code systems, and fixes headings and duplicate titles.

The maturity-level-2 trial-use guide transports and maps observations; it does not interpret them or solve provenance, privacy, security or consent. The public page exposes HL7 terms rather than a simple SPDX licence. Implementation Guide · Change log

Read the source · Change log

PhysioNet — PulseDB-Ext pairs real pressure periods with synthetic physical variables

Published 12 November 2026; official release, exact time unavailable. PulseDB-Ext: Blood Pressure and Synthetic Modeled Quantities 1.0.0 pairs 100,000 real radial arterial-blood-pressure periods from PulseDB with model-generated arterial radius, blood conductivity and wrist bioimpedance, plus parameter-sensitivity variants, for physics-informed cuffless-monitoring research. Each period contains 100 samples. The owner-supplied synthetic variables use a simplified cylindrical wrist geometry and assumed parameter distributions, and the source population and blood-pressure distribution limit generalisation.

Read findings, evidence and limitations

Published 12 November 2026; official release, exact time unavailable. PulseDB-Ext: Blood Pressure and Synthetic Modeled Quantities 1.0.0 pairs 100,000 real radial arterial-blood-pressure periods from PulseDB with model-generated arterial radius, blood conductivity and wrist bioimpedance, plus parameter-sensitivity variants, for physics-informed cuffless-monitoring research. Each period contains 100 samples.

The owner-supplied synthetic variables use a simplified cylindrical wrist geometry and assumed parameter distributions, and the source population and blood-pressure distribution limit generalisation. No independent validation was reported. The 2.3-GB collection was not downloaded; it is openly released under the Open Data Commons Attribution License 1.0. Official release

Read the source · Official release

Coverage

Coverage ran from the last approved Medical Data cutoff, 12 November 2026 at 05:31:57 UTC, through 13 November at 05:03:00 UTC, with a rolling seven-day catch-up. PubMed, Europe PMC, medRxiv, arXiv, MICCAI, MIDL and MLHC surfaces were checked alongside the full publisher registry and official medical-data and imaging release sources. Web of Science and Scopus were unavailable through an authorized searchable connection. Europe PMC’s REST endpoint was inaccessible, same-day PubMed propagation was incomplete, and IEEE and RSNA current-page coverage was sparse or stale. Nature HTML opens redirected to an identity endpoint, but the official publisher reference PDFs for both included Nature articles were accessible. Publisher pages for seven 12 November journal items and two PhysioNet releases exposed a date but no time, so their relationship to the 05:31:57 UTC lower bound remains unresolved. No qualifying new release was verified from TCIA, EUCAIM/Cancer Imaging Europe, NCI/IDC or MONAI. Source failure is not evidence of no news. No patient-level records, DICOM/CT files, datasets, package artifacts or model weights were retrieved.

Verification: two independent source checks passed; experiments were not independently reproduced.

Latest Medical data briefing